SX1233IMLTRT Semtech, SX1233IMLTRT Datasheet - Page 39

RF Transceiver Extended Bands Japan-Korea

SX1233IMLTRT

Manufacturer Part Number
SX1233IMLTRT
Description
RF Transceiver Extended Bands Japan-Korea
Manufacturer
Semtech
Datasheet

Specifications of SX1233IMLTRT

Transmitting Current
95mA
Data Rate
600Kbps
Rf Ic Case Style
QFN
No. Of Pins
24
Supply Voltage Range
1.8V To 3.6V
Operating Temperature Range
-40°C To +85°C
Receiving Current
17mA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1233IMLTRT
Manufacturer:
INFINEON
Quantity:
4 300
4.2.4. Rx Start Procedure
As described in the former sections, the RxReady interrupt warns the uC that the receiver is ready.
4.2.5. Optimized Frequency Hopping Sequences
In a frequency hopping-like application, it is required to turn off the transmitter when hopping from one channel to another,
to avoid spectral splatter and obtain the best spectral purity.
(0) SX1233 is in Tx mode in Ch A
(1) Program the SX1233 in Rx mode
(2) Change the carrier frequency in the RegFrf registers
(3) Turn the transceiver back to Tx mode
(4) Respect the Tx start procedure, described in section 4.2.2
(0) SX1233 is in Rx mode in Ch A
(1) Change the carrier frequency in the RegFrf registers
(2) Program the SX1233 in FS mode
(3) Turn the transceiver back to Rx mode
(4) Respect the Rx start procedure, described in section 4.2.4
Note
Rev 5 - June 2011
ADVANCED COMMUNICATIONS & SENSING
In Continuous mode with Bit Synchronizer, the receiver will start locking its Bit Synchronizer on a minimum or 12 bits of
received preamble (see section 3.5.13 for details), before the reception of correct Data, or Sync Word (if enabled) can
occur.
In Continuous mode without Bit Synchronizer, valid data will be available on DIO2/DATA right after the RxReady
interrupt.
In Packet mode, the receiver will start locking its Bit Synchronizer on a minimum or 12 bits of received preamble (see
section 3.5.13 for details), before the reception of correct Data, or Sync Word (if enabled) can occur.
Transmitter hop from Ch A to Ch B: it is advised to step through the Rx mode:
Receiver hop from Ch A to Ch B:
all sequences described above are assuming that the sequencer is turned on (SequencerOff=0 in RegOpMode).
Page 39
DATASHEET
www.semtech.com
SX1233