ADM7001XACT1XP Lantiq, ADM7001XACT1XP Datasheet - Page 82

no-image

ADM7001XACT1XP

Manufacturer Part Number
ADM7001XACT1XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of ADM7001XACT1XP

Lead Free Status / RoHS Status
Supplier Unconfirmed
Figure 33
Table 34
Parameter
TXD to TXCLK Rising Setup
Time
TXD to TXCLK Rising Hold
Time
TXEN asserts to data transmit
to medium (100M)
TXEN asserts to data transmit
to medium (10M)
TXEN asserts to CRS Assert
(100M Half)
TXEN asserts to CRS Assert
(10M Half)
TXEN de-asserts to finish
transmitting (100M)
TXEN de-asserts to finish
transmitting (10M)
TXEN de-asserts to CRS de-
asserts (100M)
TXEN de-asserts to CRS de-
asserts (10M)
5.5
5.5.1
Data Sheet
MII Transmit Timing
MII Transmit Timing
GPSI Timing
GPSI Receive Timing
Symbol
t
t
t
t
t
t
t
t
t
t
MT_DSETUP
MT_DHOLD
MT_TXE2MH100
MT_TXE2MH10
MT_TXE2CSH100
MT_TXE2CSH10
MT_TXE2ML100
MT_TXE2ML10
MT_TXE2CSL100
MT_TXE2CSL10
Min.
10
10
82
Typ.
Values
Max.
25
25
75
350
15
200
95
660
15
190
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Electrical Characteristics
Rev. 1.07, 2005-09-12
Note /
Test Condition
Data sheet
ADM7001