SJA1000 NXP Semiconductors, SJA1000 Datasheet - Page 36

SJA1000

Manufacturer Part Number
SJA1000
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SJA1000

Data Rate
1000Kbps
Number Of Transceivers
1
Power Down Mode
Sleep
Standard Supported
CAN 2.0B
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.5V
Package Type
PDIP
Supply Current
15mA
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Through Hole
Pin Count
28
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SJA1000
Manufacturer:
PHILIPS
Quantity:
1 000
Part Number:
SJA1000
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
SJA1000N
Manufacturer:
NXP
Quantity:
5 510
Part Number:
SJA1000N
Manufacturer:
ST
0
Part Number:
SJA1000N
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Company:
Part Number:
SJA1000N
Quantity:
140
Part Number:
SJA1000T
Manufacturer:
NXP
Quantity:
1
Part Number:
SJA1000T
Quantity:
1 747
Part Number:
SJA1000T
Manufacturer:
PHI
Quantity:
1 000
Part Number:
SJA1000T
Manufacturer:
NXP
Quantity:
20 000
Part Number:
SJA1000T
Quantity:
952
Part Number:
SJA1000T
Quantity:
952
Part Number:
SJA1000T SJ
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SJA1000T/N1
Manufacturer:
NXP
Quantity:
8 000
Part Number:
SJA1000T/N1
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SJA1000T/N1
0
Part Number:
SJA1000T/N1,118
Manufacturer:
XILINX
Quantity:
125
Philips Semiconductors
6.4.9
This register contains information about the type and location of errors on the bus. The error code capture register
appears to the CPU as a read only memory.
Table 19 Bit interpretation of the error code capture register (ECC); CAN address 12
Notes
1. For bit interpretation of bits ECC.7 and ECC.6 see Table 20.
2. For bit interpretation of bits ECC.4 to ECC.0 see Table 21.
Table 20 Bit interpretation of bits ECC.7 and ECC.6
2000 Jan 04
ECC.7
ECC.6
ECC.5
ECC.4
ECC.3
ECC.2
ECC.1
ECC.0
Stand-alone CAN controller
BIT
BIT ECC.7
(1)
(1)
(2)
(2)
(2)
(2)
(2)
E
RROR
0
0
1
1
ERRC1
ERRC0
DIR
SEG4
SEG3
SEG2
SEG1
SEG0
SYMBOL
C
ODE
C
APTURE REGISTER
Error Code 1
Error Code 0
Direction
Segment 4
Segment 3
Segment 2
Segment 1
Segment 0
BIT ECC.6
NAME
0
1
0
1
(ECC)
bit error
form error
stuff error
other type of error
VALUE
36
1
0
RX; error occurred during reception
TX; error occurred during transmission
FUNCTION
FUNCTION
Product specification
SJA1000

Related parts for SJA1000