TLF14CB1230R6 Taiyo Yuden, TLF14CB1230R6 Datasheet - Page 8

no-image

TLF14CB1230R6

Manufacturer Part Number
TLF14CB1230R6
Description
CHOKE COMMON MODE 12000UH
Manufacturer
Taiyo Yuden
Series
TLF14CBr
Datasheet

Specifications of TLF14CB1230R6

Inductance
12mH
Current
600mA
Filter Type
Common Mode - 2 Line Array
Package / Case
0.867" L x 0.669" W x 0.906" H (22.00mm x 17.00mm x 23.00mm)
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Impedance
-
Dc Resistance (dcr)
-
16.Thermnal shock
17.Damp heat
18. Loading under damp heat
19.Loading at high temperature
RELIABILITY DATA  
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
Appearance:No abnormality
Impedance change : Refer to individual specifi-
cation
Appearance:No abnormality
Inductance change : Refer to individual specifi-
cation
BUーRA Type
CMーRA/
CMーRB Type
Specified Value
・Withstanding voltage:No abnormality
・Insulation resistance:No abnormality
TLF9UA・TLF25RA:
Inductance change:Within±15%
TLF14CB:
TLF9UA・TLF25RA:
Inductance change :Within±15%
TLF14CB:
Withstanding voltage:No abnormality
Insulation resistance:No abnormality
Withstanding voltage:No abnormality
Insulation resistance:No abnormality
Withstanding voltage : No abnormality Insula-
tion resistance:No abnormality
TLF14CB
TLF9U
TLF25RA
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
CM, TLF:
According to JIS C0025
Conditions for 1 cycle
Number of cycles:10
Recovery : At least 1hr of recovery under the standard
TLF:
Temperature:60±2℃
※TLF14CB Temperature:40±2℃
Humidity:90∼95%RH
Duration:500 hrs
Recovery : At least 1hr of recovery under the standard
CM:
Temperature:40±2℃
Humidity:90∼95%RH
Duration:500 (+12, ー0) hrs
Applied current:Rated current
TLF:
Temperature:60±2℃
※TLF14CB Temperature:40±2℃
Humidity:90∼95%RH
Duration:100 hrs
Applied voltage : Apply the following specified voltage
※TLF14CB Duration : 500 hrs Apply rated current
Recovery : At least 1hr of recovery under the standard
TLF:
Temperature:85±2℃
Duration:100 hrs
Applied voltage : Apply the following specified voltage
※TLF14CB Duration:500 hrs
Apply rated current across windings
Recovery : At least 1hr of recovery under the standard
Recovery:1 to 2hrs of recovery under the standard con-
Step
TLF9UA、25RA
TLF9UB
TLF9UA、25RA
TLF9UB
1
2
3
4
removal from test chamber followed by the
measurement within 2 hrs.
removal from test chamber followed by the
measurement within 2 hrs.
condition after the removal from test chamber,
followed by the measurement within 2 hrs.
dition after the removal from test chamber.
removal from test chamber followed by the
measurement within 2 hrs.
Temperature 〔℃〕
Room Temperature
Room Temperature
Test method and remarks
between windings.
between windings.
ー25±3
+85±2
250VAC
50VDC
250VAC
50VDC
across windings
Duration 〔min〕
Within 3
Within 3
30±3
30±3
3/4