TLF14CB1230R6 Taiyo Yuden, TLF14CB1230R6 Datasheet - Page 6

no-image

TLF14CB1230R6

Manufacturer Part Number
TLF14CB1230R6
Description
CHOKE COMMON MODE 12000UH
Manufacturer
Taiyo Yuden
Series
TLF14CBr
Datasheet

Specifications of TLF14CB1230R6

Inductance
12mH
Current
600mA
Filter Type
Common Mode - 2 Line Array
Package / Case
0.867" L x 0.669" W x 0.906" H (22.00mm x 17.00mm x 23.00mm)
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Impedance
-
Dc Resistance (dcr)
-
1.Operating Temperature
Range
2.Storage temperature range
3.Rated current
4.Inductance
5.DC resistance
6.Terminal strength
tensile force
7.Temperature rise
8.Insulation resistance
between wires
9.Insulation resistance
between wire and core
RELIABILITY DATA 
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
ー25∼+105℃
ー40∼+85℃
Within the specifed range
Within the specifed tolerance
Within the specifed tolerance
No abnormality
Refer to individual specification
100MΩmin.
BUーRA Type
CMーRA/
CMーRB Type
Specified Value
100MΩmin.
TLF9U:ー25∼+115℃
TLF14CB:ー20∼+105℃
45℃ max.
TLF14CB
TLF9U
ー25∼+105℃
TLF25RA
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
Including temperature rise due to selfーgenerated heat.
CM:
The maximum DC value having temperature increase
within specified temperature, as detailed in individual
specification.
TLF9UA, 14CB, 25RA:
The maximum AC value having temperature increase
within 45℃ by the application of AC current.
TLF9UB:
The maximum DC value having temperature increase
within 45℃ by the application of DC current.
CM:
Measuring equipmet:4262A (HP) or its equivalent
Measuring frequency:1kHz
TLF9U, 25RA:
Measuring equipment:Impedance analyzer (HP4192A)
Measuring frequency:1kHz
Measuring voltage:0.35Vosc
TLF14CB:
Measuring equipment:LCR meter 4284A or its equivalent
Measuring frequency:1kHz
Measuring voltage:1.0V
CM, TLF:
Measuring equipment:DC ohmmeter
CM:
Fix the component in the direction to draw terminal
and gradually apply tensile force as detailed in indiviual
specifications.
TLF9U:
Apply the stated tensile force gradually in the direction
to draw terminal.
TLF14CB:
Apply the stated tensile force gradually in the direction
to draw terminal.
TLF25RA:
Apply the tensile force of 10N in the direction to draw
terminal for 5 seconds.
TLF:
Resistance substitution method
Applied current:Rated current
Duration:1 hr
CM・TLF:
Applied voltage:Rated voltage (CMーRA/BUーRA、CMーRB)
Duration:60sec.
TLF:
Applied voltage:500VDC (TLF9UA、14CB)
Duration:60 sec.
Nominal wire diameter tensile φd
Nominal wire diameter tensile φd
〔mm〕
〔mm〕
:500VDC (TLF9UA、14CB、25RA)
:250VDC (TLF 9UB)
:250VDC (TLF 9UB)
φ0.6
φ0.8
Test method and remarks
or its equivalent
〔N〕
〔N〕
force
force
10
5
1/4
duration
duration
〔S〕
30±5
〔S〕
30±5
401
5