8-1393792-5 TE Connectivity, 8-1393792-5 Datasheet - Page 435

Electromechanical Relay DPDT 3A 5VDC 168Ohm Through Hole

8-1393792-5

Manufacturer Part Number
8-1393792-5
Description
Electromechanical Relay DPDT 3A 5VDC 168Ohm Through Hole
Manufacturer
TE Connectivity
Type
Signal Relayr
Datasheets

Specifications of 8-1393792-5

Contact Arrangement
DPDT
Dc Coil Voltage
5 V
Coil Current
29.76 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
5V
Contact Form
2 Form C
Voltage Rating (vdc)
220V
Voltage Rating (vac)
250V
Dropout Volt (min)
0.25VDCV
Coil Resistance
168Ohm
Pick-up Voltage (max)
4VDC
Maximum Power Rating
60W/125VA
Operate Time
5ms
Contact Current Rating
3A
Contact Material
AgNi/Au
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
11mm
Product Depth (mm)
10mm
Product Length (mm)
20.2mm
Operating Temp Range
-25C to 85C
Pin Count
8
Mounting Style
Through Hole
Termination Style
PC Pin
Package / Case
DIP
Lead Free Status / Rohs Status
Compliant
Dimensions are shown for
reference purposes only.
Timing Modes
Timing Specifications
Timing Ranges: 6 to 180 cycles; 0.1 to 3 / 0.1 to 10 / 0.33 to 10 / 1 to 30 / 4
Timing Adjustment: Knob or fixed time (internal fixed resistor) – all models;
Accuracy: Repeat Accuracy:
Reset Time: 25 ms.
Relay Operate Time: Off-Delay mode: 30 ms; Interval mode: 20 ms..
Relay Release Time: On-Delay mode only: 15 ms.
Contact Data @ 25 C
Arrangements: 2 Form C (DPDT).
Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC; 345VA.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 500,000 operations, min., at rated resistive load.
Initial Dielectric Strength
Between Terminals and Case: 1,000VAC plus twice the nominal voltage
Outline Dimensions
Wiring Diagrams (Bottom Views)
On-Delay, Off-Delay and Interval.
Fixed or Knob
Off-Delay
Adjust
Same polarity.
Overall Accuracy:
1.97
(50)
to 120 sec.; 0.33 to 10 / 1 to 30 / 2 to 60 min.; 0.33 to 10
hr. (All are +5%, –0% of maximum values).
customer supplied external potentiometer or resistor
– On-Delay and Interval models only.
1.97
(50)
On-Delay & Interval
(18)
Fixed or Knob
.70
for one minute.
Adjust
0.5% 0.004 sec.
2% max.
Insulated, shielded two-
conductor cable similar
to Belden 8719, 8720 or
8769 required for leads
longer than 6 inches.
Max. permissble length
is 50 feet.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
3.25
(83)
External Potentiomer
On-Delay & Interval
or Resistor Adjust
Catalog 1308242
Issued 3-03
SCB/SCC
Specification Grade Discrete Plug-in
Time Delay Relay
• On-Delay, Off-Delay and Interval timing modes
• 13 timing ranges from 0.1 sec. to 60 min.
• 10A DPDT output contacts
• Knob, fixed or external timing adjustment.
• Rated for pilot duty
• Premium components
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Input Data @ 25 C
Voltage: See Ordering Information section for details.
Power Requirement: 3W, max.
Transient Protection: Non-repetitive transients of the following magni-
tudes will not cause spurious operation of affect function and accuracy.
Environmental Data
Temperature Range:
Mechanical Data
Mounting/Termination:
Weight: SCB: 5.3 oz. (149g) approx.; SCC: 7.5 oz. (210g) approx.
Ordering Information
Authorized distributors are likely to stock the following:
None at present.
Series SCB
Series SCC
Industrial
Discrete
SCB
Timer
Storage: SCB and SCC: -40 C to +85 C.
Operating: SCB: -30 C to +65 C; SCC: -30 C to +50 C.
SCB: UL recognized. Optional 8- or 11-pin octal-type sockets may be
SCC: 8- or 11-pin octal type sockets supplied with timer. (Must be used
RX = 8- or 11-pin
LA = 8-pin socket p/n
LC = 11-pin socket p/n
Mounting Series SCB
Mounting Series SCC
|
Specifications and availability
subject to change.
File 3520
File LR51332
socket (order
separately)
BCSA08SC for
operating mode
01 or 03 with knob
adjust or fixed
time.
BCSA11SC for
operating mode
02; or 01 or 03
with external
potentiometer or
resistor.
ordered separately.
to qualify as "UL Listed" device.)
Operating Voltage
All except 12 & 24
RX
|
|
|
|
|
|
|
|
01 = On-Delay
02 = Off-Delay
03 = Interval
Operating Mode
12 & 24
01
|
series
2XX = DPDT
(All "X's" must be included to complete part number)
Output
2XX
®
A = 120VAC, 50/60 Hz.
B = 240VAC, 50/60 Hz.
E = 24VAC, 50/60 Hz. /
F = 48VAC, 50/60 Hz. /
Q = 12VDC
|
|
|
|
|
Relay
®
Operating Voltage
/ 120VDC
24VDC
48VDC
<0.1 ms
(+10%, –15%)
3,000V
File E60363
File E60363 (SCC only)
Consult Factory
A
|
|
|
|
|
|
|
|
|
|
|
|
|
A =0 .1 to 3 sec.
B = 0.5 to 15 sec.
C = 1 to 30 sec.
D = 2 to 60 sec.
E = 4 to 120 sec.
F = 6 to 180 sec.
G = 10 to 300 sec.
I = 2 to 60 min.
K = 3 to 180 cycles
L = 0.33 to 10 min.
M = 0.5 to 15 min.
N = 1 to 30 min.
P = 0.1 to 10 min.
Timing Range
<1 ms
2,500
A
|
XA = Knob Adjust
XB = External
XF =Fixed Times –
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Timing Adjustment
Potentiometer or
resistor (Operating
modes 1 and 3 only).
Specify time delay
in seconds per the
following examples:
XF9.000 = 9 sec.
XF99.00 = 99 sec.
XF999.0 = 9999 sec.
XF1000 = 1000 sec.
AGASTAT
XA
|
|
|
|
|
|
|
|
|
|
|
|
|
1235

Related parts for 8-1393792-5