PFC500-1024F POWER ONE, PFC500-1024F Datasheet - Page 3

Linear & Switching Power Supplies 500W 24V 21A

PFC500-1024F

Manufacturer Part Number
PFC500-1024F
Description
Linear & Switching Power Supplies 500W 24V 21A
Manufacturer
POWER ONE
Type
Metal Caser
Datasheet

Specifications of PFC500-1024F

Input Voltage
85 to 264V
Number Of Outputs
1
Mounting Style
Desktop
Output Current (max)
21A
Output Voltage
24V
Input Frequency
47 to 63Hz
Efficiency
75%
Screening Level
Commercial
Product Length (mm)
228.6mm
Product Height (mm)
63.5mm
Product Depth (mm)
127mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
9
Product
Switching
Commercial/medical
Commercial
Output Power Rating
500 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
20 A
Dimensions
8.5 in L x 4.75 in W x 2 in H
Output Type
AC/DC
Brand/series
PFC500 Series
Configuration
Enclosed
Current, Input
7.8 A (RMS) (Max.) @ 85 VAC
Current, Output
21 A (Max.)
Frequency, Operating
100 kHz (Nom.)
Line Regulation
0.005
Load Regulation
0.002
Mounting Type
Surface Mount
Operation
Switching
Output
24 VDC @ 21 A
Power, Output
500 W
Power, Rating
500 W (Nom.)
Primary Type
AC-DC
Special Features
Current Share, PFC, Power Fail, Power Good Signals, Remote Sense
Standards
CE Marked
Temperature, Operating
0 °C to 50 °C @ 100% Load
Voltage, Input
85 to 264 VAC
Voltage, Output
24 VDC
Lead Free Status / RoHS Status
Not Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Not Compliant
AUG 01, 2003 revised to JUL 13, 2006
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst (PFC500)
EFT/Burst (PDC500)
Input Transient Protection
Insulation Resistance
Leakage Current (PFC500)
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Forced Air Cooling
Temperature Coefficient
Relative Humidity
Shock
Vibration
Options
DESCRIPTION
Isolation Diodes
Fan
Metric Mounting
CONDITIONS/DESCRIPTION
UL1950. UL 60950 / CSA60950-00 (cULus Mark)
EN60950 (TÜV). PDC500 (Pending).
Meets reinforced insulation of IEC60950.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 4.
Per EN61000-4-4, level 4.
PFC500 Per EN61000-4-5 class 3. PDC500 (class 2)
Input to output.
Per EN60950, 264 VAC.
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
Derate linearly above 50°C by 2.5% per °C.
Forced air cooling of 300 LFM (400 LFM for PDC500) is required if the internal
fan is not specified Cooling air velocity is measured at the output exiting window
(2.5” x 5”). Airflow direction is from the input section to the output section.
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Operating: 10±3mSec, 3 axis, Half Sine.
Non-operating: 10±3mSec, 3 axis, Half Sine.
Operating:
Non-operating:
NOTES
Add “D” as a suffix to the model number to order factory installed isolation diodes
for parallel or redundant operation. For 24V models with the “D” option, external caps
are required to meet the 1% noise/ripple spec. Power Good has a pull-up
resistor of 475
Add “F” as a suffix to the model number to order integral fan.
Fan provides the required 300 LFM (400 LFM for PDC500) of forced air cooling,
or otherwise provided by the end user.
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts.
5-32Hz
32-2000Hz Sinusoidal
on the 24V models. See Application Note #P1 for details.
Page 3 of 4
Line to Ground (PDC500)
Line to Ground (PFC500)
PFC500/PDC500 Series Data Sheet
Line to Line (PDC500)
Line to Line (PFC500)
At 100% load
At 50% load
TBD
MIN
0.5
0.5
MIN
-55
10
±4
B
B
8
1
2
0
0
5
(266.7mm x 127.0mm x 63.5mm)
Approved
±0.02
NOM
NOM
10.50" x 5.00" x 2.50"
10
www.power-one.com
SIZE IMPACT
N/A
N/A
±0.05
0.02
6.15
MAX
MAX
10k
40k
2.0
50
70
85
95
20
40
1
ASL Ft.
ASL Ft.
in (DA)
Class
UNITS
UNITS
%/°C
%RH
G
V/M
M
G
mA
kV
kV
kV
kV
°C
°C
°C
RMS
G
PK

Related parts for PFC500-1024F