PFC500-1028F POWER ONE, PFC500-1028F Datasheet

Linear & Switching Power Supplies 500W 28V 17.9A

PFC500-1028F

Manufacturer Part Number
PFC500-1028F
Description
Linear & Switching Power Supplies 500W 28V 17.9A
Manufacturer
POWER ONE
Type
Metal Caser
Datasheet

Specifications of PFC500-1028F

Output Current (max)
17.9A
Input Voltage
85 to 264V
Output Voltage
28V
Number Of Outputs
1
Input Frequency
47 to 63Hz
Efficiency
75%
Screening Level
Commercial
Product Length (mm)
228.6mm
Product Height (mm)
63.5mm
Product Depth (mm)
127mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Desktop
Pin Count
9
Product
Switching
Output Voltage (channel 1)
48 V
Output Current (channel 1)
10.4 A
Dimensions
228.6 mm L x 127 mm W x 63.5 mm H
Brand/series
PFC500 Series
Configuration
Enclosed
Current, Input
7.8 A (RMS) (Max.) @ 85 VAC
Current, Output
17.9 A (Max.)
Frequency, Operating
100 kHz (Nom.)
Line Regulation
0.005
Load Regulation
0.002
Mounting Type
Surface Mount
Operation
Switching
Output
28 VDC @ 17.9 A
Power, Output
500 W
Power, Rating
500 W (Nom.)
Primary Type
AC-DC
Special Features
Current Share, PFC, Power Fail, Power Good Signals, Remote Sense
Standards
CE Marked
Temperature, Operating
0 °C to 50 °C @ 100% Load
Voltage, Input
85 to 264 VAC
Voltage, Output
28 VDC
Lead Free Status / RoHS Status
Not Compliant
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PFC500-1028F
Manufacturer:
PWR
Quantity:
9
AUG 01, 2003 revised to JUL 13, 2006
Description
Single-Output Model Selection
PFC500-1024/PDC500-1024D 24V
PFC500-1028
PFC500-1048
NOTES:
PFC500 Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-Up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
The PFC500/PDC500 products of the PerFormanCe Power Series combine high performance midrange power with
high power density (4.4 watts/in3) and high reliability to meet the requirements of communications, commercial, and
industrial systems.
Providing tightly regulated DC power, the PFC500/PDC500 delivers full output performance with only 300 Linear Feet
per Minute (LFM) forced-air cooling (factory-installed fan optional). Main channel current sharing is provided for
redundant applications, and AC input units can be paralleled with DC input versions. Units are available with SAE
mountings or optional metric mountings.
The PFC500/PDC500 product line is approved to the latest international regulatory standards, and displays the CE
Mark.
(NOTE 1)
MODEL
1) For AC input, use PFC500 prefix; use PDC500 prefix for DC input versions.
2) Consult factory for availability of 28V and 48V units with DC input.
3) Output currents ratings are expressed with 300 LFM forced air.
4) Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units.
5) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
For ripple/noise on “D” option models, see options data on page 3.
(NOTE 2)
(NOTE 2)
VOLTAGE
OUTPUT
28V
48V
CONDITIONS/DESCRIPTION
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, F10A, 250V.
Internally limited by thermistor, one cycle, 25°C.
Per EN61000-3-2.
Switching frequency of main transformer.
21.6V to 26.4V
25.2V to 30.8V
46.0V to 56.0V
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 3)
Page 1 of 4
17.9A
10.4A
21A
• RoHS lead solder exemption compliant
• Power Factor Correction meets EN61000-3-2 (AC input
• Fully-regulated outputs
• Remote sense
• Logic level Inhibit
• Current Share, Power Fail, and Power Good Signals
• Overtemperature, overvoltage, and overcurrent protected
• Available with metric or SAE mountings
• Input transient & ESD compliance to
• Fan output voltage and optional fan
• Optional isolation diodes for parallel or redundant
• DC input versions (36-75VDC)
Features
versions)
EN61000-4-2/-3/-4/-5
operation
REGULATION
PFC500/PDC500 Series Data Sheet
0.5%
0.5%
0.5%
LINE
REGULATION (NOTE 4)
110 VAC
220 VAC
0.2%
0.2%
0.5%
LOAD
0.98
MIN
85
47
85
20
RIPPLE & NOISE
%p-p (NOTE 5)
1%
1%
1%
NOM
100
www.power-one.com
23.88V to 24.12V
27.86V to 28.14V
47.52V to 48.48V
INITIAL SETTING
ACCURACY
MAX
264
7.8
63
35
65
UNITS
W/VA
A
VAC
VAC
A
kHz
ms
Hz
RMS
PK

Related parts for PFC500-1028F

PFC500-1028F Summary of contents

Page 1

... Providing tightly regulated DC power, the PFC500/PDC500 delivers full output performance with only 300 Linear Feet per Minute (LFM) forced-air cooling (factory-installed fan optional). Main channel current sharing is provided for redundant applications, and AC input units can be paralleled with DC input versions ...

Page 2

... Turn-on Delay Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. Interface Signals and Internal Protection (PFC500 and PDC500) PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. ...

Page 3

... Per EN61000-4-2, level 4. Radiated Susceptibility Per EN61000-4-3, level 3. EFT/Burst (PFC500) Per EN61000-4-4, level 4. EFT/Burst (PDC500) Per EN61000-4-4, level 4. Input Transient Protection PFC500 Per EN61000-4-5 class 3. PDC500 (class 2) Insulation Resistance Input to output. Leakage Current (PFC500) Per EN60950, 264 VAC. Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating ...

Page 4

... TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. AUG 01, 2003 revised to JUL 13, 2006 PFC500/PDC500 Series Data Sheet Overall Length With Fan: 10.50" (266.7mm) Weight: 4.3 lb (1.95 kg) ...

Related keywords