70IMX4-15-8 POWER ONE, 70IMX4-15-8 Datasheet - Page 11

no-image

70IMX4-15-8

Manufacturer Part Number
70IMX4-15-8
Description
Module DC-DC 1-OUT 15V 0.28A 4.2W 13-Pin DIL
Manufacturer
POWER ONE
Type
Step Downr
Datasheet

Specifications of 70IMX4-15-8

Package
13DIL
Output Current
0.28(Typ) A
Output Voltage
15 V
Input Voltage
70 V
Number Of Outputs
1
Output Power
4.2(Typ) W
BCD20006-G Rev AA, 8-Apr-09
Table 12: Pin allocation for standard and option Z
Table 13: Pin allocation for option K
Standards and Approvals
The converters are approved according to UL 60950, CAN/CSA
C22.2-60950, IEC 60950-1:2001, and EN 60950 -1:2004
The converters have been evaluated for:
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the
respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Description of Options
Option K: Alternative Pinout
This pinout is compatible with other converters on the market,
for instance with the IPS3 series.
Option Z: Open Frame
For applications, where the protection of the case is not
• Building-in
• Basic insulation input to output, based on their maximum
Pin
Pin
10
11
14
16
22
23
10
11
12
13
15
24
2
3
1
2
Fig. 18
Foot print
Single-output models
Single-output models
Vo+
Vo–
Vo–
Vo+
n.c.
n.c.
Vi+
Vi+
Vi+
Vi–
Vi–
Vi–
-
-
-
-
®
13
12
Bottom view
Dual-output models
Dual-output models
10013a
Vo+
Vo–
Vi+
Vi+
Vi–
Vi–
Go
Vo–
Vo+
24
Vi+
Vi–
Go
Go
1
-
-
-
Page 11 of 12
A CB Scheme is available. The converters are subject to
manufacturing surveillance in accordance with the above
mentioned standards and with ISO 9001:2000.
Railway Applications
To comply with railway standards, all components are coated
with a protective lacquer (except option Z).
Protection Degree
The protection degree of the converters is IP 30, except open-
frame models (option Z).
Cleaning Agents
In order to avoid possible damage, any penetration of cleaning
fluids should be prevented, since the power supplies are not
hermetical sealed.
However, the open-frame models (option Z) leave the factory
unlacquered, and may be cleaned and lacquered by the
customer, for instance together with the mother board. Consult
Power-One for suitable cleaning agents.
Isolation
The electric strength test is performed in the factory as routine
test in accordance with EN 50116 and IEC/EN 60950, and
should not be repeated in the field. Power-One will not honor
any warranty claims resulting from electric-strength field tests.
Table 14: Electric strength test voltages
necessary or in the case that the motherboard should be
cleaned and lacquered with the converter fitted.
Option G: RoHS-6
Converters with a type designation ending with G are RoHS-
compatible for all six substances.
• Pollution degree 2 environment
• Connecting the input to a secondary circuit, which is subject
Characteristic
Factory test >1 s
Equivalent DC test voltage
Coupling capacitance
Insulation resist. (500 VDC)
input voltage
to a maximum transient rating of 1500 V for 20IMX4 and
40IMX4, and 2000 V for 70IMX4 models.
IMX4 DC-DC Series Data Sheet
4-Watt DC-DC Converters
20/40IMX4
~1.1
>100
1.2
1.5
Input to output
www.power-one.com
70IMX4
>100
~1.1
1.5
2.0
kVDC
kVAC
Unit
M
nF

Related parts for 70IMX4-15-8