70IMX4-15-8 POWER ONE, 70IMX4-15-8 Datasheet
70IMX4-15-8
Specifications of 70IMX4-15-8
Related parts for 70IMX4-15-8
70IMX4-15-8 Summary of contents
Page 1
... CE-marked. A special feature is their small case size, DIL 24 with only 8.5 mm profile. The circuit is comprised of integrated planar magnetics, and all components are automatically assembled and solidly soldered onto a single PCB without any wire connection ...
Page 2
... Page IMX4 DC-DC Series Data Sheet 4-Watt DC-DC Converters Efficiency Model typ [%] 79 20IMX4-03-8 80 40IMX4-03-8 81 20IMX4-05-8 81 40IMX4-05-8 81 70IMX4-05-8 82 20IMX4-12-8 82 40IMX4-12-8 82 70IMX4-12-8 82 20IMX4-15-8 82 40IMX4-15-8 82 70IMX4-15-8 81 20IMX4-0505-8 81 40IMX4-0505-8 81 70IMX4-0505-8 82 20IMX4-1212-8 82 40IMX4-1212-8 82 20IMX4-1515-8 82 40IMX4-1515-8 83 20IMX4-2424-8 83 40IMX4-2424-8 20 IMX4 - www.power-one.com 2 Options Z,G Z,G K, Z,G K, Z,G G Z,G Z,G ...
Page 3
Functional Description The IMX4 Series converters are feedback-controlled flyback converters using current mode Modulation). The input is protected against transients by means of a suppressor diode. The output voltage is monitored by a separate transformer winding close to the ...
Page 4
... 14 Vi– 20IMX4 40IMX4 100 100 V www.power-one.com 70IMX4 Unit 40 121 VDC 70 150 0.25 0 0.15 F 5.6 A approx. 400kHz 04035b 70IMX4 330 F 200 V ...
Page 5
... Model 20IMX4 Peak pulse 40IMX4 current 70IMX4 600 W 10.3 A 600 W 4.1 A 600 W 2.9 A 04036b Vi+ D Vi– 70IMX4 330 H, 0.65 0.3 A 100 F, 200 V – Page IMX4 DC-DC Series Data Sheet 4-Watt DC-DC Converters Fuse type Fast 1 A Fast 0.5 A Fast 0.315 A www.power-one.com ...
Page 6
... The current limit is primary side controlled. 3 Sum of both outputs. 4 Conditions for specified output. Other output loaded with constant current MHz 6 Measured with a probe according to EN 61204. 7 Not available for 70IMX4 models. BCD20006-G Rev AA, 8-Apr-09 is specified. C 3.3 V min typ max min typ max I = 0.5 I 3.27 3 ...
Page 7
Thermal Considerations If a converter, mounted on a PCB, is located in free, quasi- stationary air (convection cooling) at the maximum ambient temperature T (see table Temperature specifications) and A max is operated at nominal input voltage and output ...
Page 8
[ 12.8 12.4 12 11.6 11 Fig. 13 Flexible load distribution on dual outputs ( with load variation from 0 to 150 nom Output 2 ...
Page 9
... Fig. 15b Typical disturbance voltage (peak) at the pos. input according to EN 55011/55022, measured at V Output leads 0.1 m, twisted. Input capacitors see table 3. (40IMX4-05-8Z). 70IMX4-15-8, Peak Vi+, conducted, 0. MHz, Uster, 1-Sep-06 dbμ 330 μ ohm, lead length 10 cm 0.2 0 Fig. 15c Typical disturbance voltage (peak) at the pos. input according to EN 55011/55022, measured at V Output leads 0 ...
Page 10
Immunity to Environmental Conditions Table 9: Mechanical and climatic stress Test Method Standard Ca Damp heat IEC/EN 60068-2-78 steady state MIL-STD-810D section 507.2 Ea Shock IEC/EN 60068-2-27 (half-sinusoidal) MIL-STD-810D section 516.3 Eb Bump IEC/EN 60068-2-29 (half-sinusoidal) MIL-STD-810D section 516.3 ...
Page 11
... Pollution degree 2 environment • Connecting the input to a secondary circuit, which is subject maximum transient rating of 1500 V for 20IMX4 and 40IMX4, and 2000 V for 70IMX4 models Scheme is available. The converters are subject to manufacturing surveillance in accordance with the above mentioned standards and with ISO 9001:2000. ...
Page 12
IMX4 Series DC-DC converters carrying the CE- mark are in conformity with the provisions of the Low Voltage Directive (LVD) 2006/95/EC of the European Communities. Conformity with the directives is presumed by conformity ...