M29W160EB7AN6E NUMONYX, M29W160EB7AN6E Datasheet - Page 32

no-image

M29W160EB7AN6E

Manufacturer Part Number
M29W160EB7AN6E
Description
Flash Mem Parallel 3V/3.3V 16M-Bit 2M x 8/1M x 16 70ns 48-Pin TSOP Tray
Manufacturer
NUMONYX
Datasheet

Specifications of M29W160EB7AN6E

Package
48TSOP
Cell Type
NOR
Density
16 Mb
Architecture
Sectored
Block Organization
Asymmetrical
Location Of Boot Block
Bottom
Typical Operating Supply Voltage
3|3.3 V
Sector Size
8KByte x 2|16KByte x 1|32KByte x 1|64KByte x 31
Timing Type
Asynchronous
Operating Temperature
-40 to 85 °C
Interface Type
Parallel
M29W160ET, M29W160EB
APPENDIX B. COMMON FLASH INTERFACE (CFI)
The Common Flash Interface is a JEDEC ap-
proved, standardized data structure that can be
read from the Flash memory device. It allows a
system software to query the device to determine
various electrical and timing parameters, density
information and functions supported by the mem-
ory. The system can interface easily with the de-
vice, enabling the software to upgrade itself when
necessary.
When the CFI Query Command is issued the de-
vice enters CFI Query mode and the data structure
is read from the memory. Tables 22, 23, 24, 25, 26
Table 22. Query Structure Overview
Note: Query data are always presented on the lowest order data outputs.
Table 23. CFI Query Identification String
Note: Query data are always presented on the lowest order data outputs (DQ7-DQ0) only. DQ8-DQ15 are ‘0’.
32/42
1Ah
x16
10h
12h
13h
14h
15h
16h
17h
18h
19h
11h
1Bh
x16
10h
27h
40h
61h
Address
Address
2Ah
2Ch
2Eh
20h
22h
24h
26h
28h
30h
32h
34h
x8
C2h
4Eh
20h
36h
80h
x8
0051h
0052h
0059h
0002h
0000h
0040h
0000h
0000h
0000h
0000h
0000h
Data
CFI Query Identification String
System Interface Information
Device Geometry Definition
Primary Algorithm-specific Extended
Query table
Security Code Area
Query Unique ASCII String "QRY"
Primary Algorithm Command Set and Control Interface ID code 16 bit
ID code defining a specific algorithm
Address for Primary Algorithm extended Query table (see Table 25)
Alternate Vendor Command Set and Control Interface ID Code second
vendor - specified algorithm supported
Address for Alternate Algorithm extended Query table
Sub-section Name
and 27 show the addresses used to retrieve the
data.
The CFI data structure also contains a security
area where a 64 bit unique security number is writ-
ten (see Table 27, Security Code area). This area
can be accessed only in Read mode by the final
user. It is impossible to change the security num-
ber after it has been written by Numonyx. Issue a
Read command to return to Read mode.
Note: The Common Flash Interface is only avail-
able for Temperature range 6 (–40 to 85°C).
Description
Command set ID and algorithm data offset
Device timing & voltage information
Flash device layout
Additional information specific to the Primary
Algorithm (optional)
64 bit unique device number
Description
Compatible
P = 40h
Value
AMD
"Q"
"R"
"Y"
NA
NA

Related parts for M29W160EB7AN6E