0750180014 Molex Inc, 0750180014 Datasheet - Page 3

Conn Board to Board HDR 108 POS 1.5mm Solder RA Thru-Hole Tray

0750180014

Manufacturer Part Number
0750180014
Description
Conn Board to Board HDR 108 POS 1.5mm Solder RA Thru-Hole Tray
Manufacturer
Molex Inc
Type
Board to Boardr
Series
Plateau HS Dock™ 75018r
Datasheets

Specifications of 0750180014

Pitch
1.5 mm
Number Of Rows
3
Number Of Contacts
108
Gender
HDR
Contact Plating
Gold|Tin-Lead
Termination Method
Solder
Connector Type
Shrouded
Number Of Positions
108
Number Of Positions Loaded
All
Row Spacing
-
Height Stacking (mating)
-
Molding Height Above Board
0.424" (10.78mm)
Contact Mating Length
-
Mounting Type
Through Hole, Right Angle
Termination
Solder
Contact Finish
Gold
Contact Finish Thickness
30µin (0.76µm)
Features
Board Guide
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
REVISION:
DOCUMENT NUMBER:
4.0 INSERTION AND WITHDRAWAL
C
connectors. It also describes the special zippering feature of this connector which allows for the full rotation of
the connector about a specific point of rotation.
This section describes the preferred methods for inserting and withdrawing the High Speed Mezzanine
4.1 Preferred Method of Insertion and Withdrawal:
AS-75005-001
ECR/ECN INFORMATION:
EC No:
DATE:
UCP2003-2204
2003 / 04 / 09
APPLICATION SPECIFICATION
Figure 2
HIGH SPEED MEZZANINE
Figure 1
TITLE:
CREATED / REVISED BY:
Ken Stiles
BOARD TO BOARD CONNECTOR SYSTEM
APPLICATION SPECIFICATION FOR THE
WITHDRAWAL
INSERTION
HIGH SPEED MEZZANINE
Rotation
Rotation
Point
Point
Figure 1 is the preferred method of insertion. Straight
insertion of the connectors insures proper alignment
during the mating process.
Zippering during Insertion:
The “zippering” together of the connectors during
insertion is permissible. This can reduce the amount of
force required to insert the connector. However, to do
this the mating connector must be properly placed at the
point of rotation. See Figure 2.
requires more force during the withdrawal
process.
Zippering during Withdrawal:
Zippering the connector during the withdrawal
process is the preferred method of withdrawing the
connector. This allows for reduced withdrawal
forces. The connector is designed to rotate fully
about its point of rotation during the withdrawal
process, without binding or damaging the
components of the connector.
The connector may also be withdrawn evenly with
out damaging any components of the connector.
This method is less preferable only because it