HIGH SPEED MEZZANINE PRODUCT SPECIFICATION BOARD TO BOARD CONNECTOR 75005 Receptacle Assembly 1.0 2.0 3.0 4.0 5.0 6.0 7.0 REVISION: ECR/ECN INFORMATION: UCP2003-2204 EC No: B DATE: 2003 / DOCUMENT NUMBER: PS-75005-001 HIGH SPEED MEZZANINE 75003 Plug ...
Page 2
HIGH SPEED MEZZANINE PRODUCT SPECIFICATION 1.0 Scope This specification is intended to define the mechanical, electrical, and environmental requirements for the High Speed Mezzanine connector system. The interface consists of a differential pair of signal lines over molded in plastic ...
Page 3
HIGH SPEED MEZZANINE PRODUCT SPECIFICATION 4.0 RATINGS Operating Voltage Operating Temperature: -20 Current: 1.5 A Max Per Contact Product Life: 10 years Durability: 25 cycles 5.0 REQUIREMENTS 5.1 Qualification Connectors furnished under this specification shall be capable ...
Page 4
HIGH SPEED MEZZANINE PRODUCT SPECIFICATION 5.3.2 Durability: Mate and unmate for 25 cycles at 500 cycles per hour, without physical damage or exceeding a change in contact resistance of 10 mOhms. Test per EIA-364-09. 5.3.3 Durability (Preconditioning): Mate and unmate ...
Page 5
HIGH SPEED MEZZANINE PRODUCT SPECIFICATION 5.4.2 Temperature Life: There shall be no change in contact resistance greater than 10mOhms from initial when mated specimens are subjected to 85 17, Method A, Test Condition 4. 5.4.3 Temperature Life (preconditioning): There shall ...
Page 6
HIGH SPEED MEZZANINE PRODUCT SPECIFICATION 6.0 TEST SEQUENCES Test or Examination LLCR or Contact Resistance (5.2.1) Dielectric Withstanding Voltage (5.2.2) Durability (5.3.2) Durability (preconditioning) (5.3.3) Reseating (5.3.4) Vibration (5.3.5) Thermal Shock (5.4.1) Temperature Life (5.4.2) Temperature Life (preconditioning) (5.4.3) Humidity ...
Page 7