SI2493-C-FT Silicon Laboratories Inc, SI2493-C-FT Datasheet - Page 30

no-image

SI2493-C-FT

Manufacturer Part Number
SI2493-C-FT
Description
56 KBPS, V.92 ISOMODEM SYSTEM-SIDE - LEAD-FREE TSSOP 0 TO 7
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI2493-C-FT

Mfg Application Notes
SI2493/57/34/15/04, Appl Note AN93
Data Format
V.21, V.22, V.23, V.29, V.32, V.34, V.90, V.92, Bell 103, Bell 212A
Baud Rates
56k
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI2493-C-FT
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
SI2493-C-FTR
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Company:
Part Number:
SI2493-C-FTR
Quantity:
1 559
AN93
30
Dn
En
E0
E1
Command
Dial
The dial command, which may be followed by one or more dial command modifiers, dials a phone
number:
Local DTE echo.
Disable.
Enable.
Table 18. Basic AT Command Set (Continued)
Modifier
! or &
, or <
@
W
G
P
L
T
;
Rev. 0.9
Action
Flash hook-switch for U4F (FHT) ms (default: 500
ms)
Pause before continuing for S8 seconds (default: 2
seconds)
Return to AT command mode after verifying dial
tone and dialing any digits.
Wait for silence. Returns “No Answer” when call is
terminated without a silent period after ringing.
Telephone voting mode. This modifier, intended for
use in Japan, enables a special dial-in voting mode
that may be used with certain automated voting
systems. When this modifier is placed anywhere in
the dial string (e.g, ATDG), the Si2493/57/34/15/04
dials the phone number and waits S7 seconds (60
by default) to detect a busy tone. When the busy
tone is detected, the Si2493/57/34/15/04 reports
whether a polarity reversal occurs between the
time the last digit is dialed and the detection of the
busy tone. If the S7 timeout occurs prior to a busy
tone detect, “NO CARRIER” will be reported.
Polarity reversal monitoring begins after the last
digit is dialed and ends when a busy tone is
detected or S7 times out.
The Si2493/57/34/15/04 reports either “POLARITY
REVERSAL” or “NO POLARITY REVERSAL”. It is
not possible to establish a modem connection
when using this command.
Radial Last Number
Pulse (rotary) dialing—pulse digits: 0, 1, 2, 3, 4, 5,
6, 7, 8, 9
Tone (DTMF) dialing—DTMF digits: *, #, A, B, C,
D, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
Wait for dial tone before continuing for S14 sec-
onds (default: 12 seconds). Blind dialing modes
X0, X1, and X3 do not affect the W command.
If the DOP bit (U7A, bit 7) is set, the “ATDTW”
command causes the Si2457/34/15 to pause dial-
ing and either report an “OK” if a dial tone is
detected or “NO DIALTONE” if a dial tone is not
detected.
Function

Related parts for SI2493-C-FT