72-7222 TENMA, 72-7222 Datasheet - Page 20

MULTIMETER, DIGITAL, CLAMP, 3-1/2 DIGIT

72-7222

Manufacturer Part Number
72-7222
Description
MULTIMETER, DIGITAL, CLAMP, 3-1/2 DIGIT
Manufacturer
TENMA
Datasheet

Specifications of 72-7222

Dmm Type
Clamp
Voltage Measuring Range Dc
200mV To 600V
Voltage Measuring Range Ac
2V To 600V
Current Measuring Range Ac
2A To 400A
Temperature Measuring Range
-40°C To +1000°C
Measurement Operation(5)
D.Testing Diodes
To avoid damage to the Meter or to the devices under
test, disconnect circuit power and discharge all the
high-voltage capacitors before testing diodes.
Use the diode test to check diodes, transistors, and other
semiconductor devices. The diode test sends a current
voltage drop across the junction. A good silicon junction
drops between 0.5V and 0.8V.
To test the diode out of a circuit, connect the Meter as
follows:
through the semicondutor junction, then measure the
1. Insert the red test lead into the
2. Set the rotary switch to
3. For forward voltage drop readings on any semiconductor
the black test lead into the COM terminal.
button to select
component, place the red test lead on the component’s
anode and place the black test lead on the component’s
cathode.
Warning
(see figure 6)
measurement mode.
19
Model 72-7222: OPERATING MANUAL
and press SELECT
red
V terminal and
black