PAXCDC10 Red Lion Controls, PAXCDC10 Datasheet - Page 21

RS485 Serial Communications Output Interface Card With Terminal Block

PAXCDC10

Manufacturer Part Number
PAXCDC10
Description
RS485 Serial Communications Output Interface Card With Terminal Block
Manufacturer
Red Lion Controls
Datasheets

Specifications of PAXCDC10

Accessory Type
RS485 Serial Communications Output Interface Card With Terminal Block
Brand/series
PAX Series
Card Type
RS485 Serial Communications Output Card
Data Rate
7⁄8 Bits
Standards
cULus Listed, CSA Certified and CE Marked
Voltage, Working
50 V
Pax Label Kit
189 Different Engineering Units, Labels Inserted Inside the Unit
For Use With
Red Lion PAX Digital Input Panel Meters
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
the chosen setpoint is programmed, the display will default to
the next setpoint to be programmed and continue the sequence for each setpoint.
Pressing PAR at
the corresponding setpoint annunciator of an “on” alarm output. Reverse (
displays the corresponding setpoint annunciator of an “off” alarm output.

“on” alarm output.
6.6 MODULE 6 - S
” in the following parameters will reflect the chosen setpoint number.) After


Select a setpoint (alarm output) to open the remaining module menu. (The

PAR
disables the display of the setpoint annunciator. Normal (
flashes the display and the corresponding setpoint annunciator of an
6-SPt
Setpoint
SPSEL
Select
PAR
















Operation
PARAMETER
Standby
Stb-n

be installed into the PAX (see Ordering Information). Depending on the card installed, there will be two or four setpoint outputs
available. This section replaces the bulletin that comes with the setpoint plug-in card. Please discard the separate literature when using
the Plug-in card with the Digital PAX. For maximum input frequency, unused Setpoints should be configured for

Module 6 is the programming for the setpoint (alarms) output parameters. To have setpoint outputs, a setpoint Plug-in card needs to
The setpoint assignment and the setpoint action determine certain setpoint feature availability. The chart below illustrates this.
SETPOINT ANNUNCIATORS*
Annunciators
Setpoint
Lit-n
SETPOINT SELECT
Hysteresis
will exit Module 6.
Annunciators
Output Logic
Power Up State
Setpoint Value
Setpoint Tracking
Boundary Type
Standby Operation
Setpoint Hysteresis
Setpoint Off Delay
Setpoint On Delay
Setpoint Time Out
Counter Auto Reset
Reset With Display Reset
Reset When SPn+1 Activates
Reset When SPn+1 Deactivates
Setpoint


HYS-n

DESCRIPTION
OUt-n
Output

Logic


tOFF-n
Off Time
Delay
SETPOINT PARAMETER AVAILABILITY

ETPOINT
Power-up
SUP-n
State

tON-n
On Time

Delay

TIMED OUT
PARAMETER MENU


Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
) displays
ACt-n
Setpoint
. Select
Action
(A

tOUt-n
Time-out
)
Value
LARM
BOUNDARY
21
RATE

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Assignment
deactivated. Reverse (
deactivated.
powered down.
output at power up.
*
Setpoint
ASN-n
Factory Setting can be used without affecting basic start-up.


Normal (

Auto Reset
AUtO-n
Counter
) P
will restore the output to the same state it was at before the meter was
LATCH




Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
ARAMETERS

Setpoint
) turns the output “on” when activated and “off” when
Value
SP-n
SETPOINT POWER UP STATE *
will activate the output at power up.
SETPOINT OUTPUT LOGIC *
W/Display
rSd-n

Reset
Reset
TIMED OUT
) turns the output “off” when activated and “on” when

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No


Setpoint
trC-n
Tracking
rSAS-n
w/SPn+1
Activates
Reset
COUNTER
BOUNDARY

(



Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No

Boundary
tYP-n
action.
Type
Deactivates
rSAE-n
w/SPn+1
Reset


LATCH

)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
will deactivate the
Pro

Related parts for PAXCDC10