CUB5COM1 Red Lion Controls, CUB5COM1 Datasheet - Page 12

RS485 Serial Communications Card

CUB5COM1

Manufacturer Part Number
CUB5COM1
Description
RS485 Serial Communications Card
Manufacturer
Red Lion Controls
Datasheets

Specifications of CUB5COM1

Accessory Type
RS485 Serial Communications Card
Brand/series
CUB5COM Series
Card Type
RS485 Serial Communications
Data Rate
300 to 19.2 K
Standards
UL Listed, IEC Certified
For Use With
Red Lion CUB5 Miniature Electronic 8-Digit Dual Counters And Rate Indicators
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Enter the value in seconds that the Setpoint output will be active, once the
Setpoint Value is reached.
increment digit 8 to display a “-” sign (Counter A only).
deactivated. Reverse (
deactivated.
output is “on”. Reverse (
is “off”.
powered down.
output at power up.
value (
output when the assigned display value is less than or equal to the Setpoint.
YES
value crosses into the output “off” area. Once in the output “off” area, the
Setpoint will then function per the description for Low Acting Boundary Type.
SPn tOUt
SPn VAL
SPn OUt
SPn LIt
SPn P-UP
SPn tYPE
SPn StbY
This parameter is only active if the Setpoint Action is set to time out (
Enter the desired Setpoint value. To enter a negative setpoint value,
Normal (
Normal (
SAVE
High Acting Boundary Type activates the output when the assigned display
to disable a Low Acting Setpoint at power-up, until the assigned display
This parameter only applies to Low Acting Boundary Type setpoints. Select
00000100
SPn ASN
will restore the output to the same state it was at before the meter was
HI-ACt
NOr
001. 0 0
NOr
SETPOINT OUTPUT POWER-UP STATE
) equals or exceeds the Setpoint value. Low Acting activates the
) displays the setpoint annunciator when the corresponding
) turns the output “on” when activated and “off” when
ON
NOr
NOr
SETPOINT STANDBY OPERATION
OFF
NO
SETPOINT OUTPUT TIME-OUT
will activate the output at power up.
SETPOINT BOUNDARY TYPE
SETPOINT OUTPUT LOGIC
SETPOINT ANNUNCIATOR
rEV
rEV
) turns the output “off” when activated and “on” when
SETPOINT VALUE
) displays the setpoint annunciator when the output
HI-ACt
NO
0. 0 1
Count B:
Count A:
to
Rate:
OFF
NOr
NOr
599. 9 9
LO-ACt
YES
-
0
0
9999999
to
to
seconds
9999999
999999
rEV
rEV
ON
to
OFF
99999999
will deactivate the
SAVE
t-OUt
).
12
SPn AUtO
assigned (
can occur at output start, or at output end if the Setpoint Output Action is
programmed for timed output mode. The Reset-to-Count Load selections
(“
the Counter A Reset Action selected in Module 1.
Setpoint 2 output (O1 off at O2). The “
Output Action is programmed for timed output.
Setpoint Assigned Counter is reset. The counter reset can occur by the
button, User Input, Counter Reset at Power-up or a serial Reset Counter
command.
Setpoint generated Counter Auto Reset.
SPn ChC
the output state changes. This parameter is only active for the backlight version.
Setpoint 1 output (O2 off at O1). The “
Output Action is programmed for timed output.
SP1 OFF2
SP2 OFF1
SPn rSt
CtLd-
SELECTION
This parameter automatically resets the counter to which the setpoint is
This parameter will deactivate Setpoint 1 output at the Start or End of
Selecting
This parameter enables the backlight CUB5 to switch the backlight color when
SETPOINT 1 OUTPUT OFF AT SETPOINT 2 (SP1 Only)
SETPOINT 2 OUTPUT OFF AT SETPOINT 1 (SP2 Only)
2Ero-Str
CtLd-Str
2Ero-End
CtLd-End
This output reset will not occur when the Assigned Counter is reset by a
This parameter will deactivate Setpoint 2 output at the Start or End of
SETPOINT OUTPUT RESET WITH MANUAL RESET
CHANGE DISPLAY COLOR WITH OUTPUT STATE
”) only apply to Counter A assignment. This reset may be different from
SPn ASN
NO
YES
ACTION
No Auto Reset.
Reset to Zero at the start of output activation.
Reset to Count Load value at the start of output activation.
Reset to Zero at the end of output activation (timed out only).
Reset to Count Load value at the end of output activation
(timed out only).
YES
causes the Setpoint output to deactivate (reset) when the
) each time the setpoint value is reached. The automatic reset
NO
NO
NO
NO
COUNTER AUTO RESET
YES
NO
NO
NO
NO
@2Ero-Str
-End
-End
2Ero-End
Out1-Str
Out2-Str
NO
YES
” setting only applies if Setpoint 2
” setting only applies if Setpoint 1
Out2-End
Out1-End
CtLd-Str
CtLd-End
RST

Related parts for CUB5COM1