K3SC-10 AC100-240 Omron, K3SC-10 AC100-240 Datasheet - Page 3

RS-232/USBto-422/485 CONVERTER

K3SC-10 AC100-240

Manufacturer Part Number
K3SC-10 AC100-240
Description
RS-232/USBto-422/485 CONVERTER
Manufacturer
Omron
Type
Interface Converterr
Datasheet

Specifications of K3SC-10 AC100-240

Accessory Type
Converter
Analog / Digital
Analog
Control Method
ON/OFF
Voltage Rating
100 VAC to 240 VAC
Mounting
DIN Rail
Size
30 x 80 x 78
Input Type
AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
RS-232C/USB and RS-422/485
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
K3SC-10AC100-240
K3SC10AC100240
■ Characteristics
Note: 1. With RS-232C communications, free-run mode is supported for SD and RD but not for any other signal lines.
Baud rate
Data length
Stop bit length
Communications parity
Echoback selection
Selection switch response delay
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Weight
Degree of protection
(See note 3.)
EMC
Approved standards
Memory protection
2. To use USB communications, the USB driver for the K3SC must be downloaded from the OMRON web site.
3. The enclosure ratings do not apply when USB is used.
4. The CE marking does not apply when the K3SC is used for USB.
RS-232C
interface
(See note 1.)
USB interface
(See note 2.)
RS-485
interface
RS-422
interface
http://www.fa.omron.co.jp/
Item
Maximum transmission
distance
Maximum number of
connectable Units
Maximum transmission
distance
Maximum number of
connectable Units
USB standard
Maximum transmission
distance
Maximum number of
connectable Units
Maximum transmission
distance
Maximum number of
connectable Units
Isolation
method
Malfunction
Destruction
Malfunction
Destruction
Front panel operation
parts
Terminals
Communi-
cations
Power
supply
15 m
1 Unit
5 m; hub delay time + cable delay time ≤ 70 ns
1 Unit
V1.1
500 m
31 Units (for multi-drop connection)
500 m
1 Unit
1,200/2,400/4,800/9,600/19,200/38,400 (bps)
Default setting: 9,600
7/8 bits
Default setting: 7
1/2 bits
Default setting: 2
None/even/odd
Default setting: Even
Echoback: With/without
Default setting: Without
Approx. 30 ms
20 MΩ min. measured at 500 VDC between the following:
External terminals ↔ casing
RS-232C terminals and USB port ↔ RS-422/485 terminals ↔ power supply terminals
Phototransistor coupler
Isolating transformer
1,500 VAC for 1 minute measured between the following:
External terminals ↔ casing
RS-232C terminals, USB port, RS-422 terminals, and RS-485 terminals ↔ power supply terminals
500 VAC for 1 minute measured between the following:
RS-232C terminals and USB port ↔ RS-422 terminals and RS-485 terminals
AC power supply terminals, normal/common mode: ±1,500 V
AC/DC power supply terminals, normal mode: ±480 V; common mode: ±1,500 V
Square wave with 1-ns rising edge ±1 μs, ±100 ns
10 to 55 Hz, 0.5-mm single amplitude for 10 minutes each in X, Y, and Z directions
10 to 55 Hz, 0.75-mm single amplitude for 2 hours each in X, Y, and Z directions
98 m/s
294 m/s
Approx. 150 g
Conforms to IEC standards, equivalent to IP20 (when terminal cover mounted)
Equivalent to VDE 0106/100 (when terminal cover mounted)
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Fast Transient Noise:
Immunity Burst Noise:
Immunity Surge:
Immunity Conducted Disturbance
Immunity Voltage Dip/Interrupting
UL508,
Conforms to EN61326+A1, EN61010-1 (IEC61010-1)
No protective functions (Communications data is not protected for power interruptions during communications.)
2
2
3 times each in X, Y, and Z directions
3 times each in X, Y, and Z directions
EN61326+A1
CISPR 11 Group 1 class A: CISRP16-1/-2
CISPR 11 Group 1 class A: CISRP16-1/-2
EN61326+A1
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-11:
Specification
Industry
Industry
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
10 V/m (amplitude-modulated,
80 MHz to 1 GHz) (level 3)
2 kV (power line) (level 3)
1 kV line to line (I/O signal line)
1 kV line to line
2 kV line to ground (power line)
3 V (0.15 to 80 MHz) (level 2)
0.5 cycles, 0, 180°, 100% (rated voltage)
K3SC
3

Related parts for K3SC-10 AC100-240