NT31C-ST143-EV3 Omron, NT31C-ST143-EV3 Datasheet - Page 130

no-image

NT31C-ST143-EV3

Manufacturer Part Number
NT31C-ST143-EV3
Description
5.7 8-Color Dsp,STN,Ivory,Eng
Manufacturer
Omron
Datasheet

Specifications of NT31C-ST143-EV3

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Using the High-speed NT
Link (1:N) Method
Connecting to the Host’s RS-422A/485 Port
DM Area Allocation Settings
From the Programming Device (i.e., a Programming Console or CX-Program-
mer), write the settings directly to the CPU Unit's DM Area Setup Area. After
the settings have been written, they will be enabled when the power supply is
cycled, the Unit is restarted, the communications port is restarted, or a STUP
instruction is executed.
The DM Area words that are allocated and the contents of the settings are
given in the following table.
*1
Compatible Host Units
Only OMRON’s CS/CJ-series PLCs support the high-speed 1:N NT Link
through RS-422A/RS-485. The high-speed 1:N NT Link must be established
through a Serial Communications Board/Unit. (Even CS-series Units without
the “-V1” suffix can be connected via a high-speed 1:N NT Link by mounting a
Serial Communications Board/Unit.)
Be sure to check the model number of the PLC and Board/Unit before trying
to establish the high-speed 1:N NT Link.
The following table shows which CS-series PLCs can be connected to an
NT31/NT31C with the high-speed 1:N NT Link through RS-422A/RS-485.
*1
CS
series
CJ
series
Series
Set any value between 0000 and 0009 hex for the baud rate. The same
baud rate will be used regardless of the value as long as it is between 0000
and 0009 hex.
PLC
A CS1W-SCB41(-V1) Serial Communications Board or CS1W-SCU31-V1
Serial Communications Unit is required.
m
m+1
m+6
Terminating resistance switch (TERM): ON (terminator ON = terminating
Allocated DM Area words
Port 1
---
---
in high-speed NT link
CPU Units with built-
m+10
m+11
m+16
(1:N)
Port 2
8200
0000 to 0009
000@
CS1G-CPU42/43/44/45-E(V1)
CS1H-CPU63/64/65/66/
67-E(V1)
CS1G-CPU42H/43H/44H/45H
CS1H-CPU63H/64H/65H/66H/
67H
CS1D-CPU65H/67H
CJ1G-CPU44/45
CJ1G-CPU42H/43H/44H/45H
CJ1H-CPU65H/66H/67H
CJ1M-CPU11/12/13/21/22/23
Communications Board/Unit
connection through a Serial
(*1)
Setting
CPU Units supporting
(*1)
m = DM 30000 + 100 × unit number
(*1)
resistance enabled)
(*3)
1:N NT Link Mode
Baud rate (standard)
@ = The highest unit number
of the connected PTs (0 to 7)
(*2)
(*3)
Setting Contents
(*3)
(*3)
(*1)
(*1)
Section 5-2
Model Name
CS1G
CS1H
CS1D
CJ1G
CJ1H
CJ1M
113