CJ1WBAT01 Omron, CJ1WBAT01 Datasheet - Page 5

no-image

CJ1WBAT01

Manufacturer Part Number
CJ1WBAT01
Description
BATTERY FOR CJ1M ONLY
Manufacturer
Omron
Datasheet

Specifications of CJ1WBAT01

Output Voltage
3 V
Capacity
850 mAh
Chemistry
Lithium
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Programming Languages
Function
Blocks
Tasks
Symbols
(Variables)
Data
Tracing
File Memory
Source/
Comment
Memory
Communi-
cations
Maximum number of definitions
Maximum number of instances
Type of Tasks
Number of Tasks
Type of Symbols
Data Type of Symbols
Maximum Size of Symbol
Array Symbols (Array Variables)
Number of Array Elements
Memory Capacity
Number of Samplings
Sampling Cycle
Trigger Conditions
Delay Value
Program sources, comments,
program indexes, symbol tables
Logical Ports
for Commu-
nications
CIP Commu-
nications
Specification
Peripheral (USB) Port
Serial Port
Baud Rate
Transmission Distance
Communications Method
Synchronization Method
Baud Rate
Transmission Distance
Items
Logical Ports
Extended Logical
Ports
Class 3 Connection
Type
UCMM
(Non-connection
Type)
Ladder Logic (LD),
Sequential Function Charts (SFC),
Structured Text (ST), and
Instruction Lists (IL)
2,048
2,048
Cyclic tasks
Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external interrupt
tasks)
Cyclic tasks: 128
Interrupt tasks: 256
(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic
tasks is actually 384 max.)
*1. Cannot be used in Function blocks
*2. Can be used only in Function blocks
*3. Supported only when CX-Programmer version 9.0 or later is used
32k words
One-dimensional arrays
32,000 elements max.
8,000 words
(Up to 32k words × 25 banks when EM is specified in CX-Programmer)
Bits = 31, one-word data =16, two-word data = 8, four-word data = 4
1 to 2,550 ms (Unit: 1 ms)
ON/OFF of specified bit
Data comparison of specified word
Data size: 1 word, 2 words, 4 words
Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (≥), Less Than (<), Less Than or
Equals (≤), Not Equal (≠)
−32,768 to +32,767 ms
Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.)
EM file memory (Part of the EM Area can be converted for use as file memory.)
Capacity: 3.5 Mbytes
8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.)
64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.)
Number of connections: 64
Maximum number of clients that can communicate at the same time: 32
Maximum number of servers that can communicate at the same time: 40
USB 2.0-compliant B-type connector
12 Mbps max.
5 m max.
Interface: Conforms to EIA RS-232C.
Half-duplex
Start-stop
0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps)
15 m max.
• Local symbols: Can be used only within a single task in the PLC.
• Global symbols: Can be used in all tasks in the PLC.
• BOOL (bit)
• UINT (one-word unsigned binary)
• UDINT (two-word unsigned binary)
• ULINT (four-word unsigned binary)
• INT (one-word signed binary)
• DINT (two-word signed binary)
• LINT (four-word signed binary)
• UINT BCD (one-word unsigned BCD) *1
• UDINT BCD (two-word unsigned BCD) *1
• ULINT BCD (four-word unsigned BCD) *1
• REAL (two-word floating-point)
• LREAL (four-word floating-point)
• CHANNEL (word) *1
• NUMBER (constant or number) *1
• WORD (one-word hexadecimal)
• DWORD (two-word hexadecimal)
• LWORD (four-word hexadecimal)
• STRING (1 to 255 ASCII characters)
• TIMER (timer) *2
• COUNTER (counter) *2
• User defined data types (data structures) *3
CPU64
CPU65
16,000 words
CPU66
CJ2H-
32,000 words
CPU67
CJ2H-CPU6@
CPU68
5