CJ1W-V680C12 Omron, CJ1W-V680C12 Datasheet

no-image

CJ1W-V680C12

Manufacturer Part Number
CJ1W-V680C12
Description
CJ1 2-Head V680 RFID Module
Manufacturer
Omron
Datasheet

Specifications of CJ1W-V680C12

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Visualize data transmission on
production lines.
RFID System
V680 Series
Next-Generation RFID System
Conforming to ISO/IEC 18000-3
(ISO/IEC 15693).
Managing process instructions
and histories for engine
manufacturing
Managing the manufacture of LCDs
and color filters
NEW
Managing manufacturing process
traceability
Managing dies, die histories,
and die service lives

Related parts for CJ1W-V680C12

CJ1W-V680C12 Summary of contents

Page 1

NEW RFID System V680 Series Next-Generation RFID System Conforming to ISO/IEC 18000-3 (ISO/IEC 15693). Visualize data transmission on production lines. Managing process instructions and histories for engine manufacturing Managing the manufacture of LCDs and color filters Managing manufacturing process traceability ...

Page 2

... The V680 Series can be used in many parts of the world because it meets the requirements of radio wave regulations in Japan, Europe, the U.S.A., Canada, Mexico, Singapore, Malaysia, the Philippines, China, Hong Kong, Taiwan, and Korea. Contact your OMRON sales representative for details on use in other countries. Enables High-speed Data Transmission High-speed transmission of 27 kbps achieved ...

Page 3

Easier Startup and Maintenance. Simpler Operation. Lets You Visualize Data Transmission Contributes to higher efficiency for on-site startup and maintenance. Seven maintenance modes make it easy to diagnose the optimal usage conditions for the V680 RFID System. Startup is also ...

Page 4

Visualize Data Transmission without the Need for a Host Device. Perform Simple Diagnosis of Communications Conditions. Distance Level Measurement Mode Confirms correct mounting positions for the Read/Write Antenna and ID Tag. The distance between the Read/Write Antenna and ID Tag ...

Page 5

Seven maintenance modes make it easy to diagnose the communications conditions from the front panel of the Controller or Amplifier Unit. The data can also be output from the USB port of the Controller to a personal computer or other ...

Page 6

... V680-HS63 V680-HS65 Cable length (2/12.5) M V680-D1KP58HT V680-D1KP66T-SP 32-kbyte ID Tags V680-D8KF68 SYSMAC CJ/CS Series CJ1W-V680C11/C12 CS1W-V680-C11/C12 The V680-H01-V2 can be used only with 1-channel Controllers or I/O Sensor Units. V700-A40-W Cable length (2/5/10/20/30) M The maximum extendable Two Extension Cables cable length cannot be connected to each other. ...

Page 7

Handheld Type Host Device Standard Programmable Controller SYSMAC Series Handheld Reader Writer Standard Serial AC Adapter Handheld Reader Writer (order separately) V680-CH1D V600-A22 ID Tags 1-kbyte ID Tags V680-D1KP53M V680-D1KP52MT V680-D1KP54T 8-kbyte ID Tags V680-D8KF67 V680-D8KF67M Connection List for Amplifier ...

Page 8

Ordering Information ID Tag Type Memory capacity Battery-less 1 kbyte 2 kbytes 8 kbytes 32 kbytes Read/Write Antenna (Detachable Amplifier Unit Type) Type Cylindrical Standard cable, waterproof connector Flexible cable, non- waterproof connector Standard cable, non- waterproof connector Square Standard ...

Page 9

... V680-HA63B 10M Transmission interface Model RS232C, V680-CA5D01-V2 RS422/RS485 V680-CA5D02-V2 Current consumption ( External 0.26 0.13 --- CJ1W- (See V680C11 note.) 0.32 0.26 --- CJ1W- V680C12 Current consumption ( External 0.26 0.13 --- CS1W- (See V680C11 note.) 0.32 --- 0.36 CS1W- V680C12 Model V680-CH1D V680-CHUD 0.8M V680-CHUD 1.9M ...

Page 10

Accessories (Order Separately) ID Tag Attachment Type Appearance For the V680-D1KP66T For the V680-D@KF68 To mount the V680-D1KP58HT For the V680-D1KP54T Amplifier Unit Special Extension Cable (Amplifier Unit to Controller) Cable length Appearance ...

Page 11

... Psion Teklogix Handheld Terminals We recommend connecting the V600-V680-CH-PSI Handheld Reader Writer to a Psion Teklogix WORKABOUT PRO-series Handheld Terminal. Psion Teklogix products can be purchased directly from OMRON. Handheld Terminal Set Name Handheld Terminal Set Handheld Terminal, Serial End Cap, hand strap, charger ...

Page 12

... C heat resistance: The heat resistance has been checked at 180 C for up to 200 hours, and thermal shock has been checked through testing 200 thermal cycles each of 30 minutes at 10 C/180 C. (Test samples: 22, defects This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM1030 standard. 5. For details, refer to the User's Manual (Cat. No. Z262). ...

Page 13

... Note 1. Refer to the User’s Manual (Cat. No. Z248) for data backup time for temperatures higher. 2. The total Read or Write communication frequency is called the access frequency. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM1030 standard. 4. For details, refer to the User’s Manual (Cat. No. Z248). ...

Page 14

... Note 1. The degree of protection for the Connector is IP67/IP65. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM1030 standard. 2. The Connector is not waterproof. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM1030 standard. ...

Page 15

Square Read/Write Antenna with Built-in Amplifier Item Model Ambient operating temperature (with no icing) Ambient storage temperature (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Insulation resistance 20 ...

Page 16

... Hz variable vibration, 0.2-mm double amplitude at 15 m/s sweeps and Z directions for 8 minutes each 2 150 m/s 105 (not including projections) Polycarbonate (PC) resin, ABS resin Approx. 300 g 1 CJ1W-V680C12 320 mA 260 mA --- min. at 500 VDC and Z directions 3 times each 90 mm (excluding protrusions) V680-CA5D02-V2 2 ...

Page 17

... Insulation resistance 100 M min. (at 500 VDC) between input terminals and output terminals Dielectric strength 1,500 V for 1 minute between input terminals and output terminals with a current leakage max. Weight Approx Applicable standards UL/CSA CJ1W-V680C12 words 10 words V680-CHUD 1.9M RS-232C (D-SUB 9-pin) (compatible with IBM ...

Page 18

Performance Specifications ID Tag (1-kbyte Memory) Transmission Recommended combination ID Tag Read/Write Antenna V680-D1KP52MT V680-HS52 V680-HS51 V680-D1KP52MT V680-HS52 (embedded in metallic surface: steel) V680-HS51 V680-D1KP52MT V680-HS63 V680-D1KP53M V680-HS52 V680-HS51 V680-D1KP53M V680-HS52 (embedded in metallic surface : steel) V680-HS51 Note: ...

Page 19

Recommended combination ID Tag Read/Write Antenna V680-D1KP54T V680-HS52 V680-HS63 V680-HS65 V680-D1KP66T V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not ...

Page 20

Recommended combination ID Tag Read/Write Antenna V680-D1KP66MT V680-HS52 (flush-mounted on metallic surface: steel) V680-HS63 V680-HS65 V680-D1KP66T-SP V680-HS52 V680-HS63 V680-HS65 V680-D1KP58HT V680-H01-V2 Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. ...

Page 21

ID Tag (2-kbyte Memory) Transmission Recommended combination ID Tag Read/Write Antenna V680-D2KF52M V680-HS52 V680-HS51 V680-D2KF52M V680-HS52 (embedded in metallic surface: steel) V680-HS51 V680-D2KF52M V680-HS63 V680-D2KF67 V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 Note 1. When mounting the V680-HS65, be sure to attach the ...

Page 22

Recommended combination ID Tag Read/Write Antenna V680-D2KF67M (flush- V680-HS52 mounted on metallic surface: steel) V680-HS63 V680-HS65 Note: When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not ...

Page 23

Recommended combination ID Tag Read/Write Antenna V680-D8KF67M (flush- V680-HS52 mounted on metallic surface: steel) V680-HS63 V680-HS65 V680-D8KF68/ V680-HS63 -D32KF68 V680-HS65 V680-H01-V2 Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. ...

Page 24

Recommended combination ID Tag Read/Write Antenna V680-D8KF68/ V680-HS63 -D32KF68 (Special attachment provided; flush-mounted on metallic surface: steel) V680-HS65 Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting ...

Page 25

V680-HS63 (mounted on non-metallic material) & V680-D1KP52MT (embedded in non-metallic material −50 −40 −30 −20 − V680-HS51 (embedded in metallic material) & V680-D1KP53M (embedded in non-metallic material ...

Page 26

V680-HS52 (embedded in non-metallic material) & V680-D1KP66T (mounted on non-metallic material −50 −40 −30 −20 − V680-HS65 (mounted on metallic material) & V680-D1KP66T (mounted on non-metallic material) Y 100 ...

Page 27

V680-HS63 (mounted on non-metallic material) & V680-D1KP66MT (mounted on metallic surface: steel −50 −40 −30 −20 − V680-H01-V2 (mounted on non-metallic material) & V680-D1KP58HT (mounted on non-metallic material) Y 200 150 100 ...

Page 28

V680-HS63 (mounted on non-metallic material) & V680-D2KF52M (embedded in non-metallic material −70 −60 −50 −40 −30 −20 − V680-HS63 (mounted on non-metallic material) & V680-D2KF67 (mounted on non-metallic material ...

Page 29

Memory ID Tag The values given for communications ranges are reference values. Refer to page for communications distance specifications. The communications distance will depend on the ID Tags, ambient temperature, surrounding metal, noise, and other factors. ...

Page 30

V680-HS63 (mounted on metallic material) & V680-D8KF68/-D32KF68 (mounted on non-metallic material) (Horizontal-facing ID Tag −80 −70 −60 −50 −40 −30 −20 − V680-HS63 (mounted on metallic material) & V680-D8KF68/ ...

Page 31

V680-H01-V2 (mounted on non-metallic material) & V680-D8KF68/-D32KF68 (Horizontal-facing ID Tag) Y 200 150 100 50 −250 −200 −150 −100 − V680-H01-V2 (mounted on non-metallic material) & V680-D8KF68/-32KF68 (Vertical-facing ID Tag) −250 −200 −150 100 150 200 X Y ...

Page 32

Communications Time Communications Time between Antennas and Tags 1-kbyte Memory ID Tag V680-D1KP@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63A Amplifier Unit) V680-D1KP58HT (used in combination with the V680-H01 Read/Write Antenna) ● Transmission speed: Normal mode 2,500 ...

Page 33

TAT When Using an ID Controller (Reference Values) TAT (Turn Around Time) TAT refers to the total time required from the point at which a host device (such as a personal computer) starts sending a command until a response is ...

Page 34

Memory ID Tag V680-D2KF@@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63B Amplifier Unit) Controller or ID Sensor Command Unit transmission speed setting Normal mode Read Write High-speed mode Read (See note 2.) Write Note 1. These ...

Page 35

Memory ID Tag V680-D8KF@@, V680-D32KF@@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63B Amplifier Unit) Controller or ID Sensor Command Unit transmission speed setting Normal mode Read Write High-speed mode Read (See note 2.) Write Note 1. ...

Page 36

... OFF the power, and con- tact your OMRON sales representative. 11.Dispose of this product as industrial waste. 12.Be sure to follow any other warnings, cautions, and notices given in this document ...

Page 37

Dimensions Note: All units are in millimeters unless otherwise indicated. ID Tag V680-D1KP52MT/-D2KF52M R0 dia. −0 −0.1 Case material PPS resin Filling Epoxy resin V680-D1KP66T/-D1KP66MT Mounting Hole Dimensions 4-R4 4-R3 ±0.2 25 ±0.2 Two, 25 ±0.2 ...

Page 38

Read/Write Antenna with Detachable Amplifier Unit V680-HS52-W 30 Mounting Hole Dimensions V680-HS52-R 30 Mounting Hole Dimensions V680-HS51 Mounting Hole Dimensions V680-HS63 ±0 Operation indicator 23 V680-HS63 ±0 Operation indicator 23 V680-HS65-W Operation ...

Page 39

V680-HS65-R Operation indicator 100 14 Read/Write Antenna with Built-in Amplifier Unit V680-H01-V2 Mounting Hole Dimensions Coil core 142.5 235 ±0.2 (25 dia Setting switch cover Amplifier Unit V680-HA63A/-HA63B 25 100 5 ±0.2 90 Four, 4.5-dia (Mounting ...

Page 40

... ID Controller V680-CA5D01-V2/-CA5D02-V2 Two, 4.5-dia. (Mounting holes) ID Sensor Units CJ1W-V680C11 Six operation indicators 2.7 Switches 90 4.7 Connector 2.7 31 CJ1W-V680C12 Eight operation indicators 2.7 Switches 4.7 90 24.5 2.7 31 Connectors Handheld Reader Writer V680-CHUD 10.5 V680 Series 40 RFID System Two (80) 105 CS1W-V680C11 (140 ...

Page 41

V680-CH1D Operation indicator Antenna 10.5 V680-CH1D-PSI Operation indicator Antenna 10.5 AC Adapter V600-A22 Handheld Terminal (Recommended) Recommended Handheld Terminal Psion Teklogix model 7527S-G2-@@-S (V680-A-7527S-G2-@@-S) Activate switch Reset button 25 2500 ±60 160.5 Ferrite core 33 ...

Page 42

Accessories V680-D1KP66T Attachments 4-R5.5 V600-A86 Holder V680-D8KF68/-D32KF68 Attachments V600-A81 Holder 10 V680-D1KP58HT Attachments V680-A80 20 dia. V680-D1KP54T Attachments V700-A80 Two, 6-dia Two, 3.5-dia Amplifier Unit Special Extension Cable V700-A40 2M. V700-A41 3M. V700-A42 5M. V700-A43 10M. 15 ...

Page 43

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. ...

Page 44

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 45

... São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • HEAD OFFICE Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Q151-E1-06 04/10 OMRON ARGENTINA • ...

Related keywords