CJ1WBAT01 Omron, CJ1WBAT01 Datasheet - Page 4

no-image

CJ1WBAT01

Manufacturer Part Number
CJ1WBAT01
Description
BATTERY FOR CJ1M ONLY
Manufacturer
Omron
Datasheet

Specifications of CJ1WBAT01

Output Voltage
3 V
Capacity
850 mAh
Chemistry
Lithium
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Performance Specifications
User Memory
I/O Bits
Processing
Speed
Maximum Number of Connectable Units
Maximum Number of Expansion Racks
CIO Area
Work Area
Holding Area
Auxiliary Area
Temporary Area
Timer Area
Counter Area
DM Area
EM Area
Index Registers
Cyclic Task Flag Area
Memory Card
Operating Modes
Execution Mode
Overhead Processing Time
Execution Time
Interrupts
I/O Area
Link Area
Synchronous Data Refresh Area
CPU Bus Unit Area
Special I/O Unit Area
DeviceNet Area
Internal I/O Area
Force-S/R
Enabled
Banks
Items
I/O Interrupts and
External Interrupts
Scheduled
Interrupts
When EM force-S/R
function is used *3
When automatic
address allocation
is specified
50K steps
2,560 bits
Normal Mode: 100 μs
Basic Instructions: 0.016 μs min.;
Special Instructions: 0.048 μs min.
Interrupt task startup time : 26 μs or 17 μs *
Return time to cyclic task : 11 μs or 8 μs *
* When High-speed interrupt function is used
Interrupt task startup time : 22 μs or 13 μs *
Return time to cyclic task : 11 μs or 8 μs *
* When High-speed interrupt function is used
Total per CPU Rack or Expansion Rack: 10 Units max.;
Total per PLC: 40 Units max.
3 max.
2,560 bits (160 words): Words CIO 0000 to CIO 0159
3,200 bits (200 words): Words CIO 1000 to CIO 1199
1,536 bits (96 words): Words CIO 1200 to CIO 1295
6,400 bits (400 words): Words CIO 1500 to CIO 1899
15,360 bits (960 words): Words CIO 2000 to CIO 2959
9,600 bits (600 words): Words CIO 3200 to CIO 3799
3,200 bits (200 words): Words CIO 1300 to CIO 1499
37,504 bits (2,344 words): Words CIO 3800 to CIO 6143
Cannot be used for external I/O.
8,192 bits (512 words): Words W000 to W511
Cannot be used for external I/O.
8,192 bits (512 words): Words H000 to H511
Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed.
Words H512 to H1535: These words can be used only for function blocks. They can be used only for function
block instances (i.e., they are allocated only for internal variables in function blocks).
Read-only: 31,744 bits (1,984 words)
Read/write: 16,384 bits (1,024 words) in words A448 to A1471 *
* A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and
16 bits: TR0 to TR15
4,096 timer numbers (T0000 to T4095 (separate from counters))
4,096 counter numbers (C0000 to C4095 (separate from timers))
32k words *
DM Area words for Special I/O Units: D20000 to D29599 (100 words × 96 Units)
DM Area words for CPU Bus Units: D30000 to D31599 (100 words × 16 Units)
* Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus
32k words/bank × 25 banks max.: E00_00000 to E18_32767 max. *1 *2
*1. Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU
*2. EM banks D to 18 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software
*3. Force-set/reset to the EM Area is enabled by specifying a start bank in parameter settings. (unit version
32K words × 4
banks
Bank 0 to 3
Bank 3
IR0 to IR15
These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can
be set so that they are unique in each task or so that they are shared by all tasks.)
128 flags
128 MB, 256 MB, or 512 MB
PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in
MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to
RUN Mode:
Normal Mode
• 7,168 bits (448 words): Words A0 to A447
• 24,576 bits (1,536 words): Words A10000 to A11535 *
Support Software that do not specifically support the CJ2 CPU Units.
Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU
Units.
that do not specifically support the CJ2 CPU Units.
1.2 or higher)
CPU64
this mode.
present values in I/O memory, are enabled in this mode.
Programs are executed. This is the normal operating mode.
100K steps
32K words × 4
banks
Bank 0 to 3
Bank 3
CPU65
150K steps
32K words × 10
banks
Bank 0 to 9
Bank 6 to 9
CPU66
CJ2H-
250K steps
32K words × 15
banks
Bank 0 to E
Bank 7 to E
CPU67
CJ2H-CPU6@
400K steps
32K words × 25
banks
Bank 0 to 18
Bank 11 to 18
CPU68
4