XPSMCTS32 SQUARE D, XPSMCTS32 Datasheet - Page 230

no-image

XPSMCTS32

Manufacturer Part Number
XPSMCTS32
Description
SET OF SCREW TERMINALS
Manufacturer
SQUARE D
Datasheet

Specifications of XPSMCTS32

Accessory Type
Screw Connector
Rohs Compliant
Yes
Wiring diagrams
(1) When installing base modules and modules for increasing the number of safety contacts into different electrical enclosures, run separate cables for terminals
(2) Operating status of internal electronic fuse.
Input A (U1-K1)
Input B (U2-K2)
Feedback loop
Y1-Y2
Output 13-14 (N.O.)
Output 23-24 (N.O.)
Output 33-34 (N.O.)
Output 43-44 (N.O.)
Output 53-54 (N.O.)
Output 63-64 (N.O.)
Output 73-74 (N.O.)
Output 83-84 (N.O.)
Signalling output
91-92 (N.C.)
Solid-state output
Key
Principle:
page 2/226
A1/A2 (fuse)
L (+)
N (–)
XPSECP
Wiring diagram
Functional diagram
U1-13 and U1-23.
F1
0
A1
A2
115 V
230 V
XPS ECP
T –
PE
1
Supply
voltage
(1)
+
U1
K1
K1
13
14
Characteristics:
page 2/226
K2
B1
23
24
(continued)
XPS
Base module
Channel 1
closes
K2
U2
Channel 2
closes
Y2
K1
K2
Y1
Y1
Y2
13
14
23
24
Channel 1
opens
Safety automation system solutions
Preventa™ safety relay modules type XPSECP
For increasing the number of safety contacts
References:
page 2/227
33
34
Safety outputs
43
44
Channel 2
opens
53
54
63
64
73
74
83
84
Signalling
output
91
92
Wiring Diagrams:
page 2/228
Fuse
A1/A2
(2)
Y03
Y04
To PLC
Dimensions:
page 2/260
2/229
0
10
1
2
3
4
5
6
7
8
9

Related parts for XPSMCTS32