XPSMCTS32 SQUARE D, XPSMCTS32 Datasheet - Page 138

no-image

XPSMCTS32

Manufacturer Part Number
XPSMCTS32
Description
SET OF SCREW TERMINALS
Manufacturer
SQUARE D
Datasheet

Specifications of XPSMCTS32

Accessory Type
Screw Connector
Rohs Compliant
Yes
Wiring diagrams
Automatic start
Input
N.C.
Input
N.O.
Input
EDM
Output
Rising edge monitored start
Input
N.C.
Input
N.O.
Input
Start
Input
EDM
Output
Falling edge monitored start
Input
N.C.
Input
N.O.
Input
Start
Input
EDM
Output
Key
EDM = external devices monitoring
t EDM = maximum monitoring time of external devices
t sync. = synchronization time
Non-contact safety interlock (magnetic switch) monitoring
Functional diagrams
Start test = NO
0
Start-up
Start-up
Start-up
1
t < t EDM
Magnet
present
closed
Guard
Magnet
present
t < t EDM
t < t EDM
(continued)
t < t sync.
t < t sync.
t < t sync.
not present
not present
t = t EDM
t > t EDM
Magnet
Guard
Magnet
open
Magnet
present
closed
Guard
Magnet
present
Safety automation system solutions
Preventa™ configurable safety controllers
Type XPSMC
Automatic start
Input
N.C.
Input
N.O.
Input
EDM
Output
Rising edge monitored start
Input
N.C.
Input
N.O.
Input
Start
Input
EDM
Output
Falling edge monitored start
Input
N.C.
Input
N.O.
Input
Start
Input
EDM
Output
Start test = YES
(continued)
Start-up
Start-up
Start-up
No start-up
Magnet
present
Magnet
present
closed
No start-up
Guard
No start-up
t < t sync.
t < t sync.
not present
t < t sync.
not present
Magnet
Magnet
Guard
open
t < t EDM
Magnet
present
Magnet
present
closed
Guard
t < t EDM
t < t EDM
2/137
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSMCTS32