DSEK60-06A IXYS, DSEK60-06A Datasheet

DIODE FRED 600V 2X30A TO-247AD

DSEK60-06A

Manufacturer Part Number
DSEK60-06A
Description
DIODE FRED 600V 2X30A TO-247AD
Manufacturer
IXYS
Datasheet

Specifications of DSEK60-06A

Voltage - Forward (vf) (max) @ If
1.6V @ 37A
Current - Reverse Leakage @ Vr
100µA @ 600V
Current - Average Rectified (io) (per Diode)
30A
Voltage - Dc Reverse (vr) (max)
600V
Reverse Recovery Time (trr)
50ns
Diode Type
Standard
Speed
Fast Recovery =< 500ns, > 200mA (Io)
Diode Configuration
1 Pair Common Cathode
Mounting Type
Through Hole, Radial
Package / Case
TO-247AD
Product
Fast Recovery Rectifier
Configuration
Dual Common Cathode
Reverse Voltage
600 V
Forward Voltage Drop
1.6 V @ 37 A
Recovery Time
50 ns
Forward Continuous Current
30 A
Max Surge Current
320 A
Reverse Current Ir
100 uA
Power Dissipation
125 W
Mounting Style
Through Hole
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Vrrm, (v)
600
Ifavm, D = 0.5, Total, (a)
60
Ifavm, D = 0.5, Per Diode, (a)
30
@ Tc, (°c)
85
Ifrms, (a)
50
Ifsm, 10 Ms, Tvj=45°c, (a)
300
Vf, Max, Tvj =150°c, (v)
1.40
@ If, (a)
37
Trr, Typ, Tvj =25°c, (ns)
35
Irm , Typ, Tvj =100°c, (a)
10
@ -di/dt, (a/µs)
240
Tvjm, (°c)
150
Rthjc, Max, (k/w)
1.00
Package Style
TO-247
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
DSEK30-06A
DSEK30-06A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DSEK60-06A
Manufacturer:
ABB
Quantity:
120
Part Number:
DSEK60-06A
Manufacturer:
IXYS
Quantity:
5
Part Number:
DSEK60-06A
Manufacturer:
ST
0
Part Number:
DSEK60-06A
Manufacturer:
IXYS/艾赛斯
Quantity:
20 000
© 2000 IXYS All rights reserved
Common Cathode
Fast Recovery
Epitaxial Diode (FRED)
V
V
640
Symbol
I
I
I
I
I
T
T
T
P
M
Weight
Symbol
I
V
V
r
R
R
R
t
I
Data according to IEC 60747 and refer to a single diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
FRMS
FAVM
FRM
FSM
2
R
rr
RM
T
t
VJ
VJM
stg
RSM
tot
F
T0
thJC
thCK
thJA
d
I
FAVM
ÿÿ
rating includes reverse blocking losses at T
V
600
T
T
t
T
T
T
T
T
Mounting torque
T
T
T
I
For power-loss calculations only
T
I
V
L £ 0.05 mH; T
Test Conditions
Test Conditions
V
P
F
F
RRM
VJ
C
VJ
VJ
VJ
VJ
C
VJ
VJ
VJ
VJ
R
< 10 ms; rep. rating, pulse width limited by T
= 37 A;
= 1 A; -di/dt = 100 A/ms; V
= 85°C; rectangular, d = 0.5
= 25°C
= 350 V;
= T
= 45°C;
= 150°C; t = 10 ms (50 Hz), sine
= 45°C
= 150°C; t = 10 ms (50 Hz), sine
= 25°C
= 25°C
= 125°C
= T
VJM
VJM
VJ
Type
DSEK 60-06A
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 8.3 ms (60 Hz), sine
V
V
V
T
T
I
F
VJ
VJ
R
R
R
= 100°C
= 30 A; -di
= V
= 0.8 • V
= 0.8 • V
= 150°C
= 25°C
RRM
F
RRM
RRM
/dt = 240 A/ms
R
VJM
= 30 V; T
, V
R
= 0.8 V
VJ
= 25°C
RRM
, duty cycle d = 0.5
VJM
typ.
0.25
35
10
-40...+150
-40...+150
Characteristic Values
A
0.8...1.2
Maximum Ratings
DSEK 60
375
300
320
260
280
450
420
340
320
150
125
50
30
max.
1.01
100
6
1.4
1.6
7.1
50
70
50
11
C
7
1
K/W
K/W
K/W
mW
A
A
A
A
Nm
mA
mA
mA
°C
°C
°C
ns
W
A
A
A
A
A
A
A
A
g
V
V
V
A
2
2
2
2
s
s
s
s
I
V
t
TO-247 AD
A = Anode, C = Cathode, TAB = Cathode
Features
Applications
Advantages
FAVM
rr
International standard package
JEDEC TO-247 AD
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low I
Soft recovery behavior
Epoxy meets UL 94V-0
Rectifiers in switch mode power
supplies (SMPS)
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
High reliability circuit operation
Low voltage peaks for reduced
protection circuits
Low noise switching
Low losses
Operating at lower temperature or
space saving by reduced cooling
RRM
RM
A
C
-values
= 2x 30 A
= 600 V
= 35 ns
A
C (TAB)
1 - 2

Related parts for DSEK60-06A

DSEK60-06A Summary of contents

Page 1

... L £ 0.05 mH 100° rating includes reverse blocking losses at T FAVM Data according to IEC 60747 and refer to a single diode unless otherwise stated. IXYS reserves the right to change limits, test conditions and dimensions © 2000 IXYS All rights reserved DSEK Maximum Ratings 50 ...

Page 2

... Fig. 1 Forward current versus voltage drop. Fig. 4 Dynamic parameters versus junction temperature. Fig. 7 Transient thermal impedance junction to case. © 2000 IXYS All rights reserved Fig. 2 Recovery charge versus -di /dt. F Fig. 5 Recovery time versus -di /dt. F Dimensions DSEK 60, 600 V Fig. 3 Peak reverse current versus -di /dt ...

Related keywords