MTCBA-C1-EN2-N3 Multi-Tech Systems, MTCBA-C1-EN2-N3 Datasheet - Page 21

no-image

MTCBA-C1-EN2-N3

Manufacturer Part Number
MTCBA-C1-EN2-N3
Description
ROUTER WIRELESS DUAL CDMA
Manufacturer
Multi-Tech Systems
Series
MultiModem® rCellr
Datasheets

Specifications of MTCBA-C1-EN2-N3

Function
Transceiver, CDMA, Router
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Verizon™ Networks (USA)
Interface
RJ-45, RS-232
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1066
+WIND General Indicator Unsolicited Message
The unsolicited response indicates a variety of events.
Result Examples
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
+WIND: 4
Note: General indication that AT commands are ready to be accepted
The supported events are:
<event>
10:
11:
12:
13:
14:
15:
16:
The following table indicates the correspondences between <InLevel> values and
“+WIND: <event> […]” indications that are activated.
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
Reserved
Reserved
Reserved
Reserved
Product is ready to process all AT commands
A call <idx> has been created (after ATD, +CCWA, etc.)
A call <idx> has been released (NO_CARRIER, ATH, etc.)
Network service is available
The network is lost.
Reserved
Shut down is complete
Corrupted RF calibration values (checksum mismatch)
Reserved
Reserved
Reserved
Reserved
SMS service ready indication
<IndLevel>
Value
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
Corresponding
<event>
0 and 1
2
3
4
5
6
7
8
9
10
11
12
13 and 14
15
16
Chapter 7 – Status Commands
21