Datasheets

Specifications of MTCBA-C1-EN2-N3

Function
Transceiver, CDMA, Router
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Verizon™ Networks (USA)
Interface
RJ-45, RS-232
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1066
Query Scan Sleep State +WSPS
Description:
Syntax:
Values:
Close Service Status Unsolicited Response +WSPS
Description:
Syntax:
Response Values:
Sudden Momentary Power Loss Timer $WPLTIME
Description:
Syntax:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
This specific command queries the state of the service scan. It returns the same data as the
+WSPS unsolicited message.
Command syntax: AT+WSPS: <state>
<state>
This unsolicited response indicates the a change in the power save status as it pertaining to
scanning for service
Response Syntax: +WSPS: <state>
<state>
This command sets the length of the sudden momentary power loss (SMPL) timer.
The Sudden Momentary Power Loss feature requires that a timer be set to indicate how long after
main battery loss SMPL should stay active. If power from the main battery returns to its valid
range before the timer expires then the power management circuits initiate a power on sequence
without software intervention.
The timer is set after the command to enable SMPL (AT$WSMPL=1) has been issued, it is not
set after issuing the $WPLTIME command. Once SMPL has been enabled the timer cannot be
changed until SMPL is disabled.
The setting is persistent. As a result, it is saved after a power cycle. The default is 3 (2.0
seconds).
Command Syntax: AT$WPLTIME=<State>
Command
AT+WSPS
Possible Responses
+WSPS: 0
Command
AT$WPLTIME=0
Note: Timer set to .5 secs
AT$WPLTIME=?
Note: Display parameter ranges.
AT$WPLTIME
Note: Reset to Default (2 secs)
AT$WPLTIME =5
Note: Range Check Failed
AT$WSMPL?
AT$WPLTIME= 1
Note: Cannot change timer value while SMPL is enabled
AT$WPLTIME=0
AT$WPLTIME?
Note: Display last used parameter values.
0
1
0
1
Not in power-saving state
In power-saving state
Leaving power-saving state
Entering power-saving state
Possible Responses
+WSPS: 0
OK
Possible Responses
OK
$WPLTIME: (0-3)
OK
Note: Valid parameter ranges.
OK
ERROR
$WSMPL: 1
OK
ERROR
OK
$WWPLTIME: 0
OK
Chapter 18 – Sleep Commands