Specifications of MTCBA-C1-EN2-N3

Function
Transceiver, CDMA, Router
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Verizon™ Networks (USA)
Interface
RJ-45, RS-232
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1066
Values:
Sudden Momentary Power Loss (SMPL) $WSMPL
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
This command enables or disables the Sudden Momentary Power Loss feature.
When AT+CFUN is issued SMPL is disabled to allow for a normal power down and is enabled
again on power up.
Please note that if the command receives the input value that is the currently set parameter value
it will return an error. If Sudden Momentary Power Loss is already enabled and an application
tries to enable it again the command will return an error and the same is true for disable.
The setting is persistent. As a result, it is saved after a power cycle. The default is 0 (Disabled).
An SMPL event can cause a ring indication to a host application during sleep.
Command Syntax: AT$WSMPL=<State>
<State>
0
1
2
3 (Default)
Command
AT$WSMPL=0
Note: SMPL Disabled
AT$WSMPL=?
Note: Display parameter ranges.
AT$WSMPL
Note: Reset to Default (Disabled)
AT$WSMPL =2
Note: Range Check Failed
AT$WSMPL=0
AT$WSMPL?
Note: Display last used parameter values.
AT$WSMPL=0
AT$WSMPL=0
AT$WSMPL?
Note: After SMPL
<State>
0 (Default)
1
Timer Length
0.5 Second
1.0 Second
1.5 Seconds
2.0 Seconds
Sudden Momentary Power Loss is Disabled
Sudden Momentary Power Loss is Enabled
Possible Responses
OK
$WSMPL: (0-1)
OK
Note: Valid parameter ranges.
OK
ERROR
OK
$WSMPL: 0
OK
OK
ERROR
$WSMPL: 1
Chapter 18 – Sleep Commands