ZMOTIONL100ZCOG Zilog, ZMOTIONL100ZCOG Datasheet - Page 40

no-image

ZMOTIONL100ZCOG

Manufacturer Part Number
ZMOTIONL100ZCOG
Description
EVALUATION KIT Z8FS040 ZMOTION
Manufacturer
Zilog
Series
ZMOTION™r
Datasheets

Specifications of ZMOTIONL100ZCOG

Sensor Type
Motion, PIR (Pyroelectric Infrared)
Sensing Range
5m x 5m, 60 Degree Detection Pattern
Interface
Serial
Sensitivity
Adjustable
Voltage - Supply
5V
Embedded
Yes
Utilized Ic / Part
Z8FS040B
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-2511

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZMOTIONL100ZCOG
Manufacturer:
Zilog
Quantity:
2
PS028511-0112
MD Origin (Bit 2)
EM Noise Detected (Bit 1)
EM Transient Detected (Bit 0)
Bit
Field
Control
Address
Lock Level (Bits 7–5)
Origin of last motion detection event; controlled by the PIR engine.
This bit indicates how the PIR engine detected the last Motion Detected Event. When the engine sets
the Motion Detected bit in PIRStatus0, it also sets this bit according to which detection engine
registered the event.
EM Noise Detected on PIR Signal
Set by the PIR engine; cleared by the application.
• This bit indicates if the engine has detected noise on the PIR signal. This event is provided to the user
EM Transient Detected on PIR Signal
Set by the PIR engine; cleared by the application.
• This bit indicates if the Engine has detected a transient on the PIR signal. This event is provided to
Controlled by the application.
This parameter sets the minimum slope change in the signal that can be considered valid motion. This
prevents small signal changes caused by environmental or V
Use this value in combination with PIR Sensitivity and Range Control settings to balance sensitivity and
stability to the particular lens and pyroelectric sensor being used.
• Smaller values allow subtle signals with lower slopes to be considered motion events at the expense
• Larger values allow the system to ignore smaller signal slope changes at the expense of potentially
application to indicate that an EM noise event has occurred and associated motion event(s) may have
been suppressed by the engine. This bit does not have to be read for normal operation and is
provided as status only. The application must clear this bit after it has been read.
of potential false motion events.
missing smaller motion events.
the user application to indicate that an EM transient event has occurred and associated motion
event(s) may have been suppressed by the engine. This bit does not have to be read for normal
operation and is provided as status only. The application must clear this bit after it has been read.
0 = Normal Motion Detector.
1 = Extended Motion Detector.
7
Table 19. PIR Advanced Status/Control Register 2 (ePIR_ASC2)
Lock level
R/W
6
5
Window Size
4
ZMOTION™ Detection and Control Family
R/W
F2H
CC
3
shifts from causing a false detection.
2
Window Update Rate
Product Specification
Advanced API Register Set
R/W
1
0
33