KSZ8851-16MQL Micrel Inc, KSZ8851-16MQL Datasheet - Page 74

Single Ethernet Port + Generic (16-bit) Bus Interface( )

KSZ8851-16MQL

Manufacturer Part Number
KSZ8851-16MQL
Description
Single Ethernet Port + Generic (16-bit) Bus Interface( )
Manufacturer
Micrel Inc
Datasheets

Specifications of KSZ8851-16MQL

Controller Type
Ethernet Controller, MAC/PHY
Interface
Bus
Voltage - Supply
1.8V, 2.5V, 3.3V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
128-MQFP, 128-PQFP
Operating Supply Voltage (typ)
3.3V
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
128
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-3292 - BOARD EVALUATION KSZ8851-16MLL
Current - Supply
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
576-3253

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8851-16MQL
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8851-16MQLI
Manufacturer:
MICREL
Quantity:
1 001
Part Number:
KSZ8851-16MQLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8851-16MQLI
0
0xF0 – 0xF3: Reserved
Port 1 PHY Special Control/Status, LinkMD
This register contains the special control, status and LinkMD
Port 1 Control Register (0xF6 – 0xF7): P1CR
This register contains the global per port control for the chip function.
August 2009
Bit
15
14-13
12
11
10
9
8-0
Micrel, Inc.
Bit
5
4-0
Bit
15
14
13
Default
0
0x0
0
0
0
0
0x000
Default
0
0x01
Default
0
0
0
R/W
RO
RO
RW
(Self-Clear)
RW
RO
RW
RO
R/W
RW
RW
RW
R/W
RO
RO
Description
Adv 10 Half
Link partner 10 half capability.
Reserved.
Description
Reserved
Vct_result
VCT result.
[00] = normal condition.
[01] = open condition has been detected in cable.
[10] = short condition has been detected in cable.
[11] = cable diagnostic test is failed.
Vct_en
Vct enable.
1 = the cable diagnostic test is enabled. It is self-
cleared after the VCT test is done.
0 = it indicates the cable diagnostic test is completed
and the status information is valid for read.
Force_lnk
Force link.
1 = force link pass.
0 = normal operation.
Reserved
Remote (Near-end) loopback (rlb)
1 = perform remote loopback at PHY
(RXP1/RXM1 -> TXP1/TXM1, see Figure 11)
0 = normal operation
Vct_fault_count
VCT fault count.
Distance to the fault. It’s approximately
0.4m*vct_fault_count.
Description
LED Off
1 = Turn off all of the port 1 LEDs (P1LED3, P1LED2,
P1LED1, P1LED0). These pins are driven high if this bit
is set to one.
0 = normal operation.
Txids
1 = disable the port’s transmitter.
0 = normal operation.
Restart AN
®
(0xF4 – 0xF5): P1SCLMD
®
information of PHY1.
74
Bit is same as:
Bit 0 in P1SR
Bit is same as:
Bit is same as:
Bit 0 in P1MBCR
Bit 1 in P1MBCR
Bit 9 in P1MBCR
KSZ8851-16/32 MQL/MQLI
M9999-083109-2.0

Related parts for KSZ8851-16MQL