ADSP-21061KSZ-133 Analog Devices Inc, ADSP-21061KSZ-133 Datasheet - Page 47

ADSP-21061 1MBIT, 33MHz, 5v SHARC

ADSP-21061KSZ-133

Manufacturer Part Number
ADSP-21061KSZ-133
Description
ADSP-21061 1MBIT, 33MHz, 5v SHARC
Manufacturer
Analog Devices Inc
Series
SHARC®r
Type
Floating Pointr
Datasheet

Specifications of ADSP-21061KSZ-133

Interface
Synchronous Serial Port (SSP)
Clock Rate
33MHz
Non-volatile Memory
External
On-chip Ram
128kB
Voltage - I/o
5.00V
Voltage - Core
5.00V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
240-MQFP, 240-PQFP
Package
240MQFP
Numeric And Arithmetic Format
Floating-Point
Maximum Speed
33 MHz
Ram Size
128 KB
Device Million Instructions Per Second
33 MIPS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADSP-21061KSZ-133
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ENVIRONMENTAL CONDITIONS
Thermal Characteristics
The ADSP-21061 is available in 240-lead thermally enhanced
MQFP package. The top surface of the thermally enhanced
MQFP contains a metal slug from which most of the die heat is
dissipated. The slug is flush with the top surface of the package.
Note that the metal slug is internally connected to GND
through the device substrate.
The ADSP-21061L is available in 240-lead MQFP and 225-ball
plastic BGA packages.
All packages are specified for a case temperature (T
ensure that the T
flow source may be used. A heat sink should be attached with a
thermal adhesive.
T
T
PD =Power dissipation in W (this value depends upon the spe-
cific application; a method for calculating PD is shown under
Power Dissipation).
θ
Table 29. ADSP-21061 (5 V Thermally Enhanced ED/MQFP
Package)
Table 30. ADSP-21061L (3.3 V MQFP Package)
Table 31. ADSP-21061L (3.3 V PBGA Package)
Parameter
θ
Parameter
θ
Parameter
θ
CA
CASE
CASE
CA
CA
CA
=Value from tables below.
= T
= Case temperature (measured on top surface of package)
AMB
+ ( PD
Condition (Linear Ft./Min.)
Airflow = 0
Airflow = 100
Airflow = 200
Airflow = 400
Airflow = 600
Condition (Linear Ft./Min.)
Airflow = 0
Airflow = 100
Airflow = 200
Airflow = 400
Airflow = 600
Condition (Linear Ft./Min.)
Airflow = 0
Airflow = 200
Airflow = 400
CASE
θ
is not exceeded, a heatsink and/or an air-
CA)
Typical
10
9
8
7
6
Typical
19.6
17.6
15.6
13.9
12.2
Typical
19.0
13.6
11.2
CASE
Rev. C | Page 47 of 56 | July 2007
). To
Unit
°C/W
Unit
°C/W
Unit
°C/W
ADSP-21061/ADSP-21061L