Datasheet

Specifications of ADE7755ARSZRL

Input Impedance
390 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
3mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-SSOP (0.200", 5.30mm Width)
Meter Type
Single Phase
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADE7755ZEB - BOARD EVALUATION FOR AD7755
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7755ARSZRL
Manufacturer:
FREESCALE
Quantity:
430
Company:
Part Number:
ADE7755ARSZRL
Quantity:
198
Company:
Part Number:
ADE7755ARSZRL
Quantity:
218
NO LOAD THRESHOLD
The ADE7755 also includes a no load threshold and start-up
current feature that eliminates any creep effects in the meter. The
ADE7755 is designed to issue a minimum output frequency in all
modes except when SCF = 0 and S1 = S0 = 1. The no load detection
threshold is disabled in this output mode to accommodate
specialized application of the ADE7755. Any load generating a
frequency lower than this minimum frequency will not cause a
pulse to be issued on F1, F2, or CF. The minimum output
frequency is given as 0.0014% of the full-scale output frequency
for each of the f
i
frequencies (i = 1, 2, 3, or 4), see Table 6.
Rev. A | Page 19 of 20
For example, in an energy meter with a meter constant of
100 imp/kWh on F1 and F2 using f
output frequency at F1 or F2 is 0.0014% of 3.4 Hz or 4.76 × 10
This is 3.05 × 10
load threshold is equivalent to 1.7 W of the load or a start-up
current of 8 mA at 220 V. IEC 1036 states that the meter must
start up with a load current equal to or less than 0.4% Ib. For a
5 A (Ib) meter, 0.4% Ib is equivalent to 20 mA. The start-up
current of this design therefore satisfies the IEC requirement.
As illustrated in this example, the choice of f
(i = 1, 2, 3, or 4) and the ratio of the stepper motor display
determine the start-up current.
−3
Hz at CF (64 × F1 Hz). In this example, the no
2
(3.4 Hz), the maximum
i
frequency
ADE7755
−5
Hz.