AD7147AACBZ-RL Analog Devices Inc, AD7147AACBZ-RL Datasheet - Page 50

no-image

AD7147AACBZ-RL

Manufacturer Part Number
AD7147AACBZ-RL
Description
CAPACITANCE TO DIGITAL CONVERTER
Manufacturer
Analog Devices Inc
Series
CapTouch™r
Type
Capacitive Sensor Controllerr
Datasheet

Specifications of AD7147AACBZ-RL

Resolution (bits)
16 b
Data Interface
Serial, SPI™
Voltage Supply Source
Single Supply
Voltage - Supply
2.6 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
25-WLCSP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sampling Rate (per Second)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AD7147A
Table 33. Device ID Register
Address
0x017
Table 34. Proximity Status Register
Address
0x042
Data Bit
[3:0]
[15:4]
Data Bit
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[15:12]
0
0
0
0
0
0
0
0
0
0
Default
Value
0
147
Default
Value
0
0
Type
R
R
Type
R
R
R
R
R
R
R
R
R
R
R
R
Name
REVISION_CODE
DEVID
Name
STAGE0_PROXIMITY_STATUS
STAGE1_PROXIMITY_STATUS
STAGE2_PROXIMITY_STATUS
STAGE3_PROXIMITY_STATUS
STAGE4_PROXIMITY_STATUS
STAGE5_PROXIMITY_STATUS
STAGE6_PROXIMITY_STATUS
STAGE7_PROXIMITY_STATUS
STAGE8_PROXIMITY_STATUS
STAGE9_PROXIMITY_STATUS
STAGE10_PROXIMITY_STATUS
STAGE11_PROXIMITY_STATUS
Unused
Rev. B | Page 50 of 68
Revision code
Device ID = 0001 0100 0111
STAGE0 proximity status register
1 = indicates proximity has been detected on STAGE0
STAGE1 proximity status register
1 = indicates proximity has been detected on STAGE1
STAGE2 proximity status register
1 = indicates proximity has been detected on STAGE2
STAGE3 proximity status register
1 = indicates proximity has been detected on STAGE3
STAGE4 proximity status register
1 = indicates proximity has been detected on STAGE4
STAGE5 proximity status register
1 = indicates proximity has been detected on STAGE5
STAGE6 proximity status register
1 = indicates proximity has been detected on STAGE6
STAGE7 proximity status register
1 = indicates proximity has been detected on STAGE7
STAGE8 proximity status register
1 = indicates proximity has been detected on STAGE8
STAGE9 proximity status register
1 = indicates proximity has been detected on STAGE9
STAGE10 proximity status register
1 = indicates proximity has been detected on STAGE10
STAGE11 proximity status register
1 = indicates proximity has been detected on STAGE11
Set to 0
Description
Description

Related parts for AD7147AACBZ-RL