AD7147AACBZ-RL Analog Devices Inc, AD7147AACBZ-RL Datasheet - Page 48

no-image

AD7147AACBZ-RL

Manufacturer Part Number
AD7147AACBZ-RL
Description
CAPACITANCE TO DIGITAL CONVERTER
Manufacturer
Analog Devices Inc
Series
CapTouch™r
Type
Capacitive Sensor Controllerr
Datasheet

Specifications of AD7147AACBZ-RL

Resolution (bits)
16 b
Data Interface
Serial, SPI™
Voltage Supply Source
Single Supply
Voltage - Supply
2.6 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
25-WLCSP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sampling Rate (per Second)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AD7147A
Table 30. STAGE_HIGH_INT_STATUS Register
Address
0x009
1
Registers self-clear to 0 after readback if the limits are not exceeded.
Data Bit
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[15:12]
Default
Value
0
0
0
0
0
0
0
0
0
0
0
0
Type
R
R
R
R
R
R
R
R
R
R
R
R
Name
STAGE0_HIGH_INT_STATUS
STAGE1_HIGH_INT_STATUS
STAGE2_HIGH_INT_STATUS
STAGE3_HIGH_INT_STATUS
STAGE4_HIGH_INT_STATUS
STAGE5_HIGH_INT_STATUS
STAGE6_HIGH_INT_STATUS
STAGE7_HIGH_INT_STATUS
STAGE8_HIGH_INT_STATUS
STAGE9_HIGH_INT_STATUS
STAGE10_HIGH_INT_STATUS
STAGE11_HIGH_INT_STATUS
Unused
1
Rev. B | Page 48 of 68
Description
STAGE0 CDC conversion high limit interrupt result
1 = indicates STAGE0_HIGH_THRESHOLD value was
exceeded
STAGE1 CDC conversion high limit interrupt result
1 = indicates STAGE1_HIGH_THRESHOLD value was
exceeded
STAGE2 CDC conversion high limit interrupt result
1 = indicates STAGE2_HIGH_THRESHOLD value was
exceeded
STAGE3 CDC conversion high limit interrupt result
1 = indicates STAGE3_HIGH_THRESHOLD value was
exceeded
STAGE4 CDC conversion high limit interrupt result
1 = indicates STAGE4_HIGH_THRESHOLD value was
exceeded
STAGE5 CDC conversion high limit interrupt result
1 = indicates STAGE5_HIGH_THRESHOLD value was
exceeded
STAGE6 CDC conversion high limit interrupt result
1 = indicates STAGE6_HIGH_THRESHOLD value was
exceeded
STAGE7 CDC conversion high limit interrupt result
1 = indicates STAGE7_HIGH_THRESHOLD value was
exceeded
STAGE8 CDC conversion high limit interrupt result
1 = indicates STAGE8_HIGH_THRESHOLD value was
exceeded
STAGE9 CDC conversion high limit interrupt result
1 = indicates STAGE9_HIGH_THRESHOLD value was
exceeded
STAGE10 CDC conversion high limit interrupt result
1 = indicates STAGE10_HIGH_THRESHOLD value was
exceeded
STAGE11 CDC conversion high limit interrupt result
1 = indicates STAGE11_HIGH_THRESHOLD value was
exceeded
Set to 0