490NAD91103 SQUARE D, 490NAD91103 Datasheet - Page 19

PROFIBUS PLC CONNECTOR, PLUG, 9POS

490NAD91103

Manufacturer Part Number
490NAD91103
Description
PROFIBUS PLC CONNECTOR, PLUG, 9POS
Manufacturer
SQUARE D
Series
NADr
Datasheet

Specifications of 490NAD91103

Connector Type
Programmable Logic Controller
Gender
Plug
No. Of Contacts
9
Connector Mounting
Cable
For Use With
Square D Altivar 71 Profibus DP Drives
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CONTROL UNITS
1
2
3
09/2004
Function Characteristics
Control Units
Overload Protection
Magnetic Trip Overcurrent Protection
Short-Circuit Protection
Phase Loss Protection
Phase Imbalance Protection
Ground Fault Detection (equipment protection only)
Overload Trip Class
Motor Type (AC only)
Test Function
Overtorque (Jam)
Underload
Long Starting Times
Reset Modes
Alarm
“Log” Function
“Monitoring” Function
With Function Modules
Thermal Overload Pre-alarm
Fault Differentiation and Manual Reset
Fault Differentiation and Automatic or Remote Reset
Indication of Motor Load (analog signal) 0–10 V or 4–20 mA
With Communication Module or via RS-485 Modbus
Starter Status (ready, run, trip)
Reset Mode
Alarm
Remote Reset via the Bus
Indication of Motor Load
Fault Differentiation
Remote Programming and Monitoring of all Functions
“Log” Function
“Monitoring” Function
Built-in function
LUS and LU2S require customer provided supplemental short circuit protection (fuses or circuit breaker) per national and local electric codes.
Mounting possibilities:1 function module or 1 communication module.
2
3
®
port on LUCM control unit
Manual
Automatic
or Remote
Standard
LUCA
1
14.2 x the FLA setting
14.2 x maximum rated current of the control unit
1
1
10
3-phase
1
With communication module ASILUFC5 or LULC031
1
1
Advanced
LUCB
1
1
With function module LUFDA10 or LULC031
With function module LUFW10, or
communication module LULC031
With function module LUFW
With function module LUFDH20
With function module LUFDA10
With function module LUFV
Parameters can be set via the bus.
With Modbus communication module
LULC031
(thermal overload alarm only)
3
1
LUCC
10
1
© 2004 Schneider Electric All Rights Reserved
1
TeSys® U-Line Motor Starters
LUCD
20
Single-phase
1
1
1
1
1
1
1
Multifunction
LUCM
3 to 17 x the FLA setting
1
1
1
5 to 30
Single-phase and 3-phase
1
1
1
Parameters can be set via integrated LCD
and keypad, communication module
LUFDA10 or LULC031, network
PowerSuite™ Software.
Possible for each type of fault. Indication via
integrated LCD and keypad, via remote
terminal, via PowerSuite Software.
With function module LUFW10, or
communication module LULC031
Log of the last 5 trips includes number of
starts, number of trips, number of operating
hours.
Indication on integrated LCD and keypad, via
remote terminal or PowerSuite Software.
With Modbus communication module
LULC031 and RS-485 Modbus port on the
LUCM control unit (alarm possible for all types
of fault)
With Modbus communication module
LULC031and RS-485 Modbus port on the
LUCM control unit
With Modbus communication module
LULC031and RS-485 Modbus
LUCM control unit
With Modbus communication module
LULC031and RS-485 Modbus port on the
LUCM control unit
1
1
1
1
1
1
1
1
®
port on the
1
, or
1
1
19