Current Transformer

01301

Manufacturer Part Number
01301
Description
Current Transformer
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 01301

Input Current
500A
Turns Ratio
100
Transformer Mounting
Chassis
Secondary Current Nom
5A
Power Rating
2VA
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Mounting Type
Donut
Accuracy
0.5 %
Current, Primary
500 A
Current, Ratio
500:5
Current, Secondary
5 A
Diameter, Inside
2.06 in.
Diameter, Outside
3.56 in.
Frequency Response
50 to 400 Hz
Function
Current
Material, Stud
Brass
Primary Type
Current
Range, Measurement
5 A
Standards
UL and CSA Approved
Technology
Inductive
Thickness
1.1 in.
Transformer Type
Donut
Dimensions
27.94 mm W
Number Of Outputs
1
Primary Voltage Rating
500 V
Secondary Voltage Rating
5 V
Termination Style
Round Crimp Terminals
Current Ratio
500
Leaded Process Compatible
No
Output Current
5A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
The primary wire passing through the core, or by wrapping the secondary wires leading to the meter
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
• Wide Variety of Control, Alarm, and Limit
• Calibration Not Affected by Steel Panel
• Rugged Metal Case for Rigorous Environments
• Commercially-Sealed, Moisture and Dust
Dimensions
Use
Mounting
Proof
4 - 1/2”-Model 3344AIXA & 3324AIXA
1
=
Panel Meter Cut-out Dimensions
Specifications
Accuracy:
Movement:
Suspension:
Tracking:
Repeatability:
Shielding:
Response Time:
Overload (1 sec.):
Overload (Continuous):
Dial:
Case:
Voltage Drop:
Pointer:
Scale Length:
Net Weight:
Control Point(s)
Adjustments:
Switching:
Differential:
Auto/Manual Reset:
Contacts/Output Relay:
Frequency Response:
Power:
Operating Temperature:
Circuit-to-Ground
Voltage:
NOTE:
3 - 1/2”-Model 3343AIXA & 3323AIXA
AC: ±3% of full scale; DC: ±2% F.S.
Annular, self-shielding
Pivot and jewel
±3%
Within 0.5% F.S.
Calibration is unaffected by magnetic panel mounting
1.5 seconds maximum above 10mA
AC: 7 amps; DC: 10 times F.S.
AC: 7 amps, DC: 1.5 times F.S.
Sharp clear scale. Each dial arc is calibrated to
track the specific type of movement used.
Sealed metal, plastic window
50mV
Black, knife-edge
4.05" (103.0mm)
17oz (0.48kg)
Single, high limit, 0-100% of arc; double, low limit 0-
95% of arc; high limit 5-100% of arc Adjustable to
within 4° of each other
Within 1% of indication
“On,” “Off” difference is within 0.5% of F.S.
Latching function can be enabled independently
for each relay by removing jumpers on terminal
block
DPDT relay contacts for each control point; Each
set of contacts rated at 5 amps, 120/240 VAC resistive.
50-1000Hz
108-132 VAC, 50-400Hz
+41°F to 122°F (5°C to +50°C)
250V rms maximum
DC meters meet ANSI specification C-39.1

Related parts for 01301