01301 Simpson, 01301 Datasheet - Page 20

Current Transformer

01301

Manufacturer Part Number
01301
Description
Current Transformer
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 01301

Input Current
500A
Turns Ratio
100
Transformer Mounting
Chassis
Secondary Current Nom
5A
Power Rating
2VA
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Mounting Type
Donut
Accuracy
0.5 %
Current, Primary
500 A
Current, Ratio
500:5
Current, Secondary
5 A
Diameter, Inside
2.06 in.
Diameter, Outside
3.56 in.
Frequency Response
50 to 400 Hz
Function
Current
Material, Stud
Brass
Primary Type
Current
Range, Measurement
5 A
Standards
UL and CSA Approved
Technology
Inductive
Thickness
1.1 in.
Transformer Type
Donut
Dimensions
27.94 mm W
Number Of Outputs
1
Primary Voltage Rating
500 V
Secondary Voltage Rating
5 V
Termination Style
Round Crimp Terminals
Current Ratio
500
Leaded Process Compatible
No
Output Current
5A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
The primary wire passing through the core, or by wrapping the secondary wires leading to the meter
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Models & Parameters
Accessories - Three-Phase Current Transformer
A three-phase terminal style current transformer must be used with
GIMA® three phase meters.
The current transformer is equipped with terminals to permit easy con-
nection to the GIMA units. These terminals are #8-32 brass studs and
come with a flatwasher, lockwasher and a regular nut (leads are not
provided).
Ordering Information
Catalog Number
Phase Amps
Phase Volts
Line Volts
Per Phase PK
Per Phase kW
Per Phase kvar
Per Phase kVA
3 Phase PF
3 Phase kW
3 Phase kvar
3 Phase kVA
Frequency
KWh
Capacitive kvarh
Inductive kvarh
Total kvarh
Import kvarh
Current Demand
Voltage Demand
kW Demand
Peak Amps
Peak Phase Volts
Peak Current Demand
Peak Voltage Demand
Neutral Current
37026
37027
37028
37029
37030
Current Ratio
100:5
150:5
200:5
300:5
50:5
G100 G200
X
X
X
X
X
X
X
X
X
X
X
X
Accuracy @ 60Hz
± 3%
± 1%
± 1%
± 1%
± 1%
X
X
X
X
X
X
X
X
X
X
X
X
X
G300
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Burden VA @ 60 Hz
G400
10.0
2.0
2.0
4.0
5.0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Ordering Information
Mounting Requirements
Panels should be .04 to .16 inches (1mm to 4mm) thick with a
square cut-out of 3.62” x 3.62” (92mm x 92mm.) A minimum depth
of 2.83” (72mm) should be allowed behind the panel for the meter.
Remove the panel mounting clips and insert the meter into the cut-
out from the front of the panel. Push the meter home. Ensure the
screws in each panel mount clip are fully retracted and insert the
clips as shown in the diagram below. Tighten the screws to secure
the meter firmly in the panel.
Do not overtighten.
G
For other Voltage and Current Inputs, contact Simpson Electric Company
B B a a s s i i c c U U n n i i t t
100
200
300
400
1
2
3
4
1
0
1
2
P P o o w w e e r r
V V o o l l t t a a g g e e I I n n p p u u t t s s
B B a a s s i i c c U U n n i i t t
GIMA 100 Meter
GIMA 200 Meter
GIMA 300 Meter
GIMA 400 Meter
P P o o w w e e r r S S u u p p p p l l y y
115 VAC @ 45-65Hz
230 VAC @ 45-65 Hz
V V o o l l t t a a g g e e I I n n p p u u t t
120/208V
120/240V - Split Phase
277/480V
C C u u r r r r e e n n t t I I n n p p u u t t
O O t t h h e e r r
None
5 amp
63/110V
C C u u r r r r e e n n t t I I n n p p u u t t
O O t t h h e e r r

Related parts for 01301