01301 Simpson, 01301 Datasheet - Page 19

Current Transformer

01301

Manufacturer Part Number
01301
Description
Current Transformer
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 01301

Input Current
500A
Turns Ratio
100
Transformer Mounting
Chassis
Secondary Current Nom
5A
Power Rating
2VA
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Mounting Type
Donut
Accuracy
0.5 %
Current, Primary
500 A
Current, Ratio
500:5
Current, Secondary
5 A
Diameter, Inside
2.06 in.
Diameter, Outside
3.56 in.
Frequency Response
50 to 400 Hz
Function
Current
Material, Stud
Brass
Primary Type
Current
Range, Measurement
5 A
Standards
UL and CSA Approved
Technology
Inductive
Thickness
1.1 in.
Transformer Type
Donut
Dimensions
27.94 mm W
Number Of Outputs
1
Primary Voltage Rating
500 V
Secondary Voltage Rating
5 V
Termination Style
Round Crimp Terminals
Current Ratio
500
Leaded Process Compatible
No
Output Current
5A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
The primary wire passing through the core, or by wrapping the secondary wires leading to the meter
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
• Four model types designed to fit a wide
• One meter to measure all your values
• Easy installation - software detection/
• Wide backlit LCD display for easy viewing
• Easy to use - four keys select all parameters
• Use for single or three-phase applications
range of applications
correction of wiring errors
INPUT
System
Voltages
Current
Measurement range
Operating Frequency
Harmonics
Input Loading
Overload
Auxiliary Supply
General Display
ENVIRONMENTAL
Temperature
Humidity
Programming
CT Primary
VT Primary
Pulse Outputs
Function
Pulse Length
Isolation
Scaling
ACCURACY
Current
5% to 120%FS
Voltage LN
20% to 120%FS
Voltage LL
20% to 120%FS
Watts
5% to 120%FS
VA
5% to 120%FS
var
5 % to 120%FS
PF
Frequency
Neutral Current
5% to 120%FS
Wh Register
VAh Register
Varh Register
Note:
MECHANICAL
Bezel
Depth
Panel Cutout
Weight
Height
Specifications
Measurement range
Voltage
Current
Voltage
Current
Standard
Optional
Output No. 1
Output No. 2
3-phase, 3 or 4 wire unbalanced load
120/208, 120/240, 277/480, 63/110
0.5% to 120%
5 amp from external CTs Fully Isolated
0.5% to 120%
45 to 65 Hz
Up to the 20th harmonic
Less than 0.1VA per phase
Less than 0.1VA per phase
x2 for 2 seconds max.
x40 for 1 second max.
115V±15% 45-65Hz
230V±15% 45-65Hz
Custom backlit supertwist LCD 3 lines of .47”
(12mm) digits plus .15” (3.8mm) legends
14°F to 149°F (-10°C to 65°C) operating
<75% RH non-condensing
5amp to 6500 amp
60v to 50,000v
2
Wh (G200, G300 & G400 only)
Total varh (G300 & G400 only)
100ms
2500V (50 Output No. 1 to Output No. 2)
Settable 1, 10 or 100 pulse output rate
All accuracies specified are ±1 digit
*Rdg = Reading
2.77” x 3.79” (w/ .28” lip)
2.83”
3.62” x 3.62”
14 oz.
3.79”
Per Phase
±0.2%FS
±1% Rdg*
±0.2%FS
±1% Rdg*
±0.3%FS
±1% Rdg*
±0.4%FS
±1% Rdg*
±0.6%FS
±1.5% Rdg*
±0.8%FS
±2% Rdg*
±0.2°
N/A
N/A
N/A
N/A
N/A
3 Phase
N/A
N/A
N/A
±0.6%FS
±1% Rdg*
±1%FS
±1.5% Rdg*
±1.5% FS
±2% Rdg
±0.2°FS
±0.05 Hz
±0.6% FS
±2% Rdg
Class 1
EN 61036
Class 2
Class 2
IEC 1268
more >>