CRT1-ATT01 Omron, CRT1-ATT01 Datasheet - Page 60

no-image

CRT1-ATT01

Manufacturer Part Number
CRT1-ATT01
Description
Bracket 16 Pt Slave MIL
Manufacturer
Omron
Datasheet

Specifications of CRT1-ATT01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specifications
Note. There are specifications that apply to the mounting direction and input accuracy. Refer to the next page for details.
Effects of Mounting Direction on Accuracy
A cold junction compensator is included in the Terminal Block of the CRT1-TS04T. The input accuracy depends on the mounting direction
if only the Unit is replaced.
60
Item
Input type
Indicator accuracy
Conversion cycle
Temperature conversion
data
Isolation method
Mounting method
Communications power
supply current
Weight
Mounted normally
Mounted in any direction other
than the above
Mounting direction
Temperature Input Units
model
Switchable between R, S, K, J, T, E, B, N, L, U, W, and PL2
When set with CX-Integrator: Input types can be set individually
for each input.
Wen set with DIP switch: The same input type setting applies to
all 4 inputs.
(±0.3% of indication value or ±1°C, whichever is larger) ±1 digit
max. (See note.)
250 ms/4 points
Binary data (4-digit hexadecimal when Normal Display Mode is selected or 8-digit hexadecimal when 1/100 Display Mode is
selected.)
Between input and communication lines: Photocoupler isolation
Between temperature input signals: Photocoupler isolation
35-mm DIN track mounting (See note.)
75 mA max. at 24 VDC
110 mA max. at 14 VDC
148 g max.
Indicator Accuracy in Exceptional Cases
K, T, and N below
−100°C
U and L
R and S below 200°C
B below 400°C
W
PL2
temperature range
As specified in the Performance Specifications.
±
Indicator Accuracy in Exceptional Cases
0.3% of indication value or
K, T, and N below −100°C
U and L
R and S below 200°C
B below 400°C
W
PL2
Input type and
Input type and temperature
CRT1-TS04T/-TS04P
range
CRT1-TS04T
±2°C ±1 digit max.
±2°C ±1 digit max.
±3°C ±1 digit max.
Not specified.
±0.3% of indication value or
±3°C (whichever is larger) ±1
digit max.
±0.3% of indication value or
±2°C (whichever is larger) ±1
digit max.
±
2°C (whichever is larger)
Input accuracy
Input accuracy
±3°C ±1 digit max.
±3°C ±1 digit max.
±4°C ±1 digit max.
Not specified.
±0.3% of indication value or ±4°C
(whichever is larger) ±1 digit max.
±0.3% of indication value or ±3°C
(whichever is larger)
Input accuracy
±
1 digit max.
Switchable between PT100 (−200 to 850°C) and PT100 (−200 to
200°C)
When set with CX-Integrator: Input types can be set individually
for each input.
When set with DIP switch: The same input type setting applies to
all 4 inputs.
−200 to 850°C input range:
(
digit max.
−200 to 200°C input range:
(
digit max.
75 mA max. at 24 VDC
110 mA max. at 14 VDC
147 g max.
±
±
0.3% of indication value or
0.3% of indication value or
CRT1-TS04P
±
±
0.8°C, whichever is larger)
0.5°C, whichever is larger)
±
±
1
1

Related parts for CRT1-ATT01