AFCT-5745TPZ Avago Technologies US Inc., AFCT-5745TPZ Datasheet - Page 9

no-image

AFCT-5745TPZ

Manufacturer Part Number
AFCT-5745TPZ
Description
Fiber Optic Transceiver,MODULE
Manufacturer
Avago Technologies US Inc.
Series
METRAKr
Datasheet

Specifications of AFCT-5745TPZ

Data Rate
2.7Gbps
Wavelength
1300nm
Applications
General Purpose
Voltage - Supply
3.1 V ~ 3.5 V
Connector Type
LC Duplex
Mounting Type
SFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 5. EEPROM Serial ID Memory Contents - Address A2h, Byte 110
Notes:
1. Bit 6 is logic OR’d with the SFP Tx_Disable input pin 3 ... either asserted will disable the SFP transmitter.
2. AFCT-5745Z does not respond to state changes on Rate Select Input Pin. It is internally hardwired to full bandwidth.
Table 6. EEPROM Serial ID Memory Contents - Address A2h, Bytes 112, 113, 116, 117
9
Bit #
7
6
5
4
3
2
1
0
Byte
112
113
116
117
Bit #
7
6
5
4
3
2
1
0
7
6
0-5
7
6
5
4
3
2
1
0
7
9
0-5
Status/Control Name
Tx Disable State
Soft Tx Disable
Reserved
Rx Rate Select State
Reserved
Tx Fault State
Rx LOS State
Data Ready (Bar)
Flag
Temp High
Temp Low
V
V
Tx Bias High
Tx Bias Low
Tx Power High
Tx Power Low
Rx Power High
Rx Power Low
Reserved
Temp High
Temp Low
V
V
Tx Bias High
Tx Bias Low
Tx Power High
Tx Power Low
Rx Power High
Rx Power Low
Reserved
CC
CC
CC
CC
High
Low
High
Low
Bit Name Description
Alarm Set when transceiver nternal temperature exceeds high alarm threshold.
Alarm Set when transceiver internal temperature exceeds alarm threshold.
Alarm Set when transceiver internal supply voltage exceeds high alarm threshold.
Alarm Set when transceiver internal supply voltage exceeds low alarm threshold.
Alarm Set when transceiver laser bias current exceeds high alarm threshold.
Alarm Set when transceiver laser bias current exceeds low alarm threshold.
Alarm Set when transmitted average optical power exceeds high alarm threshold.
Alarm Set when transmitted average optical power exceeds low alarm threshold.
Alarm Set when received P_Avg optical power exceeds high alarm threshold.
Alarm Set when received P_Avg optical power exceeds low alarm threshold.
Warning Set when transceiver internal temperature exceeds high warning threshold.
Warning Set when transceiver internal temperature exceeds low warning threshold.
Warning Set when transceiver internal supply voltage exceeds high warning threshold.
Warning Set when transceiver internal supply voltage exceeds low warning threshold.
Warning Set when transceiver laser bias current exceeds high warning threshold.
Warning Set when transceiver laser bias current exceeds low warning threshold.
Warning Set when transmitted average optical power exceeds high warning threshold.
Warning Set when transmitted average optical power exceeds low warning threshold.
Warning Set when received P_Avg optical power exceeds high warning threshold.
Warning Set when received P_Avg optical power exceeds low warning threshold.
Description
Digital state of SFP Tx Disable Input Pin (1 = Tx_ Disable asserted)
Read/write bit for changing digital state of SFP Tx_Disable function Note 1)
Digital state of SFP Rate Select Input Pin (1 = full bandwidth of 2.488 Gbit) (Note 2)
Digital state of The SFP Tx Fault Output Pin (1 = Tx Fault asserted)
Digital state of The SFP LOS Output Pin (1 = LOS asserted)
Indicates Transceiver is powered and Real Time sense data is Ready (0 = Ready)