E53-CK03 Omron, E53-CK03 Datasheet

RS-485 OPTION E5CK

E53-CK03

Manufacturer Part Number
E53-CK03
Description
RS-485 OPTION E5CK
Manufacturer
Omron
Type
Temperature Controllerr
Datasheets

Specifications of E53-CK03

Rohs Compliant
YES
Accessory Type
RS-485 Communications Unit
Analog / Digital
Digital
Control Method
ON/OFF and PID Control
Voltage Rating
100 V to 240 V
Mounting
Panel
Counting Method
Up or Down (Selectable)
Size
100 mm L x 58 mm W x 48 mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
E5CK
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E53CK03
Advanced, Compact Digital Controllers
• IP66/NEMA4 (indoor use) front face.
• Modular structure, one-stock type.
• Heating/cooling control.
• Serial communications (RS-232C and RS-485).
• Temperature and analog inputs.
• High-accuracy: 100 ms sampling (for analog input).
• Advanced tuning which includes fuzzy self-tuning.
• Conforms to international EMC and safety standards.
Model Number Structure
■ Model Number Legend
Refer to the following when ordering set models.
1. Constant Value/Program
2. Control Output 1/Control Output 2
Note: E5CK-VR1 and E5CK-QQ1 are not available, but with options.
Ordering Information
■ List of Models
Note: A single Output Unit and Option Unit can be mounted to each Base Unit.
E5CK-@@@@
Base Unit
Output Unit
Digital Controller
E5CK
Blank:Constant value
T:
AA:
RR:
QR:
CR:
VR:
QQ: Pulse (NPN)/Pulse (NPN)
Refer to Safety Precautions for All Temperature Controllers.
Program
Without Output Unit (field interchangeable)
Relay/Relay
Pulse (NPN)/Relay
Linear (4 to 20 mA)/Relay
Linear (0 to 10 V)/Relay
1 2 3 4
Description
Description
E5CK-AA1 AC100-240
E5CK-AA1-500 AC100-240
E5CK-TAA1 AC100-240
E5CK-TAA1-500 AC100-240
E53-R4R4
E53-Q4R4
E53-Q4HR4
E53-C4R4
E53-C4DR4
E53-V44R4
E53-Q4Q4
E53-Q4HQ4H
Model
Model
3. Auxiliary Output
4. Option
Refer to E5
procedures.
1:
01:
03:
B:
F:
Auxiliary output (1 point)
RS-232C serial communication
RS-485 serial communication
Event input (1 point)
Transfer output (4 to 20 mA)
@
K Operation for operating
Base Unit
Base Unit with terminal cover
Standard model
Standard model with terminal cover
Relay/Relay
Pulse (NPN)/Relay
Linear (4 to 20 mA)/Relay
Linear (0 to 20 mA)/Relay
Linear (0 to 10 V)/Relay
Pulse (NPN)/Pulse (NPN)
Pulse (PNP)/Pulse (PNP)
Pulse (PNP)/Relay
Specification
Specification
CSM_E5CK_DS_E_3_1
1

Related parts for E53-CK03

E53-CK03 Summary of contents

Page 1

... Transfer output ( mA) Model E5CK-AA1 AC100-240 E5CK-AA1-500 AC100-240 E5CK-TAA1 AC100-240 E5CK-TAA1-500 AC100-240 Model E53-R4R4 E53-Q4R4 E53-Q4HR4 E53-C4R4 E53-C4DR4 E53-V44R4 E53-Q4Q4 E53-Q4HQ4H CSM_E5CK_DS_E_3_1 Specification Base Unit Base Unit with terminal cover Standard model Standard model with terminal cover Specification Relay/Relay Pulse (NPN)/Relay ...

Page 2

... Input Ranges Platinum Resistance Thermometer Input (switch selectable) JPt100 °C −199.9 to 650.0 Range °F −199.9 to 999.9 Resolution (°C/°F) 0 (main setting and alarm) Model E53-CK01 E53-CK03 E53-CKB E53-CKF Model Model 100 to 240 VAC type PLII mA Pt100 −199.9 to 650.0 −199.9 to 999.9 1 E5CK ...

Page 3

Thermocouple Input (switch selectable) (See note.) °C −200 −100 Range 0 500.0 to 850 1,300 °F −300 −100 0 900.0 to 2,300 1,500 Resolution (° °F) (main setting and alarm) ...

Page 4

Characteristics Indication accuracy (See note.) Thermocouple: (±0.3% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. Hysteresis ...

Page 5

... Option Unit Ratings and Characteristics Model E53-CKB Event input E53-CK01 Communications E53-CK03 E53-CKF Transfer output Note: Event input is used for switching the target value, run or stop command, or automatic and manual mode with an external signal input. Output Type Relay Voltage (NPN) ...

Page 6

Nomenclature Operation Indicators • OUT1 Lights when the pulse output function assigned to control output 1 turns ON. • OUT2 Lights when the pulse output function assigned to control output 2 turns ON. • SUB1 Lights when the output function ...

Page 7

... Terminal Cover E53-COV07 Unit Label (Order Separately) Y92S-L1 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. (With rivet) E5CK 7 ...

Page 8

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...