E53-C3D Omron, E53-C3D Datasheet
![no-image](/images/manufacturer_photos/0/4/494/omron_sml.jpg)
E53-C3D
Specifications of E53-C3D
Related parts for E53-C3D
E53-C3D Summary of contents
Page 1
... Linear voltage VDC Communications ready RS-422 RS-485 (no board installed) E5AJ-A2H02-F E5AJ-A2H03-F E5AJ-A2HM-F E5EJ-A2H02-F E5EJ-A2H03-F E5EJ-A2HM-F Part Number Relay output E5CJ-R2HB-F E5CJ-R2-F E5CJ-R Voltage output Current output E5CJ-Q2HB-F E5CJ-C2B-F E5CJ-Q2-F E5CJ-C2-F E5CJ-Q-F E5CJ-C-F Part number E53-R E53-S E53-Q E53-Q3 E53-Q4 E53-C3 E53-C3D E53-V34 ...
Page 2
... Extreme value Stable SP range Hunting waveform monitored PID before tuning PID after tuning E53-V35 E54-CT1 E54-CT3 Part number E53-J01 E53-J02 E53-J03 Part number Y92A-48N Y92A-49N Y92A-96N Part number Y92F-30 Platinum RTD Type N 100 -200 to 1,300 -199.9 to 650.0 -300 to 2,300 -199.9 to 999.9 1 C/F ...
Page 3
... LED digits Other functions LED indicators Note control period is less than 5 seconds, use solid state relay or voltage relay. Note: 2. The E53-C3 Current Output Unit cannot be used if heater burnout alarm is used. E5EJ max., OFF: 100 k min. max., resolution of 2,600 0.5% of set point whichever is greater, 1 digit max. ...
Page 4
E5 J Specifications, Materials Mounting Weight Controller Mounting hardware Connections Enclosure Front panel ratings Rear case Terminals Approvals UL CSA Ambient Operating temperature Storage Humidity Insulation resistance Dielectric strength Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Note: ...
Page 5
E5 J Dimensions Unit: mm (inch) E5AJ E5EJ 96 (3.78 11.7 (3.78 x 3.78 ) 112 (4.41) Panel cutout (3.58 x 3.58) 120 (4.72) min. 109.7 (4.32 (3.86) 11.7 (1.89) 112 (4.41) ...
Page 6
E5 J E5CJ 208 9 (1.89 x 1.89) 58 (2.28) Panel cutout 44.8 x 44.8 (1.76 x 1.76) 60 (2.36) min 109.2 (4.30) 100 (3.94) Side-by-side mounting of several controllers 45 Recommended panel thickness is ...
Page 7
E5 J Nomenclature E5AJ without communications 1. Process value display 11. Stop (STOP) indicator 10. Output (OUT) indicator 9. Level key 8. Mode key E5CJ without communications 1. Process value display 2. Set value display 10. Output (OUT) indicator 9. ...
Page 8
E5 J Connections E5AJ, E5EJ CONTROLLERS For current For voltage For relay output output output 100 to 240 VAC, 50/ VDC Note: * E5AJ/E5EJ models with communica- tions do not have an ...
Page 9
... Two Alarm Outputs, No Event Input 100 to 240 VAC, 50/60 Hz Alarm output 1 Alarm output 2 E5CJ- CONTROLLERS No Alarm Outputs, No Event Input 100 to 240 VAC, 50/60 Hz OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC TC13 08/00 For relay output Control output Use these terminals when connecting a thermocouple ...