Unit Components
2-2-5 CompoBus/S I/O Link Unit Components
NODE ADDRESS
ON
4. Expansion I/O connecting cable
!
Caution
1, 2, 3...
SW1
Note The Long-distance Communications Mode can be used only when connected to
CPM1A-TS101/102
Do not touch the expansion I/O connecting cable while the power is being sup-
plied in order to prevent any malfunction due to static electricity.
one of the following Master Units: C200HW-SRM21-V1, CQM1-SRM21-V1, or
SRM1-C0j-V2.
0
1
2 to F
Set value
4. Expansion I/O Connecting Cable
5. Expansion Connector
1. CompoBus/S Terminals
2. DIP Switch
Connects the Temperature Sensor Unit to the expansion connector on the
PC’s CPU Unit, an Expansion I/O Unit, or another Expansion Unit. The cable
is connected to the Temperature Sensor Unit and cannot be removed.
Connects to an additional Expansion I/O Unit or another Expansion Unit.
Include the CompoBus/S communications data high/low terminal, commu-
nications power supply +/– terminals, and NC terminals. Power is supplied
to the Unit internally, so the power supply terminals can be used as relay
terminals.
The DIP switch sets the Unit’s node address, sets the communications
mode, and determines whether or not the outputs will be cleared in the event
of a communications error.
1 to 4
(labeled
1, 2, 4,
and 8)
DR
HOLD
Pin(s)
Pt100
JPt100
---
Platinum resistance
These pins set the Unit’s node address using the DIP switch pins as
binary digits. (1 = ON)
ON: Long-distance Communications Mode
OFF: High-speed Communications Mode
(See note.)
ON: Retain outputs when a communications error occurs.
OFF: Clear outputs when a communications error occurs.
12: 1100
thermometer
0: 0000
4: 0100
8: 1000
13: 1101
1: 0001
5: 0101
9: 1001
–200.0 to 650.0
–200.0 to 650.0
Setting not possible
Range (°C)
2. DIP switch
3. LED indicators
5. Expansion connector
1. CompoBus/S terminals
Function
10: 1010
14: 1110
2: 0010
6: 0110
–300.0 to 1,200.0
–300.0 to 1,200.0
Range (°F)
Section 2-2
11: 1011
15: 1111
3: 0011
7: 0111
43