D4C-1202 Omron, D4C-1202 Datasheet - Page 13

no-image

D4C-1202

Manufacturer Part Number
D4C-1202
Description
SMALL LIMIT SWITCH
Manufacturer
Omron
Series
D4Cr
Datasheets

Specifications of D4C-1202

Rohs Compliant
YES
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
5A @ 250VAC
Actuator Type
Roller Plunger
Mounting Type
Chassis Mount
Termination Style
Cable Leads
Operating Force
1177gf
Actuator Style
Roller Plunger
Operating Force Max
11.77N
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
30V
Contact Current Ac Max
5A
Contact Current Dc Max
4A
Switch Terminals
Cable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4C1202
Weather-resistant Models
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* Operation characteristics for the D4C-@@27-P and D4C- @@29-P are for a lever length of 38 mm.
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Operating Environment
Adjustable Roller Lever
D4C-@@27-P
Operating
characteristics
Operating force OF
Release force
Pretravel
Overtravel
Movement Differential MD
• Seal material may deteriorate if a Switch is used outdoor or where
• Install Switches where they will not be directly subject to cutting
• Constantly subjecting a Switch to vibration or shock can result in
• The Switches have physical contacts. Using them in environments
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
containing silicon gas will result in the formation of silicon oxide
(SiO
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Not Suitable
7
2
2
) due to arc energy. If silicon oxide accumulates on the
2
40 max.
25 ± 0.1
Precautions for Correct Use
34
RF
PT
OT
Model
max.
max.
max.
min.
min.
30R to 75R (variable)
Two, 5.1
Spot facing 10.2 dia. Depth: 6
17.5 dia. x 7 stainless
steel roller
VCTF cable, 0.75 mm
4 conductor Finishing O.D.: 7.6
11.4
23
7.5
8
+0.2
0
D4C-@@27-P
M5 (length: 16)
Allen-head bolt
M5 (length: 12)
Allen-head bolt
dia. holes
5.69 N
1.47 N
25°
40°
2
,
Suitable
2
57.7 max.
52.3 ± 0.8
1.4
D4C-@@29-P
31.5 ± 0.8
5.69 N
1.47 N
16
25°
40°
65 max.
1.5
*
Adjustable Rod Lever
D4C-@@29-P
Handling
The bottom of the Switch at the cable outlet is resin-molded. Secure
the cable at a point 5 cm from the Switch bottom to prevent exertion
of excess force on the cable.
When bending the cable, provide a bending radius of 45 mm min. so
as not to damage the cable insulation or sheath. Excessive bending
may cause fire or leakage current.
Connections
• Be sure to connect a fuse with a breaking current 1.5 to 2 times
• When using the Limit Switch for the EN ratings, use the gI or gG 10-
7
larger than the rated current to the Limit Switch in series in order to
protect the Limit Switch from damage due to short-circuiting.
A fuse.
2
2
40 max.
25 ± 0.1
34
Secure
here
5.4
3 dia. x 160 stainless
steel lever
Two, 5.1
Spot facing 10.2 dia.
Depth: 6
11.4
23
VCTF cable, 0.75 mm
4 conductor Finishing O.D.: 7.6
7.5
8
+0.2
0
5 cm
dia. holes
M5 (length: 16)
Allen-head bolt
M5 (length: 12)
Allen-head bolt
2
,
Bending radius
(R45 mm min.)
55 max.
1.4
44
31.5
16
65 max.
D4C
1.5
13

Related parts for D4C-1202