D4C-1202 Omron, D4C-1202 Datasheet

no-image

D4C-1202

Manufacturer Part Number
D4C-1202
Description
SMALL LIMIT SWITCH
Manufacturer
Omron
Series
D4Cr
Datasheets

Specifications of D4C-1202

Rohs Compliant
YES
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
5A @ 250VAC
Actuator Type
Roller Plunger
Mounting Type
Chassis Mount
Termination Style
Cable Leads
Operating Force
1177gf
Actuator Style
Roller Plunger
Operating Force Max
11.77N
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
30V
Contact Current Ac Max
5A
Contact Current Dc Max
4A
Switch Terminals
Cable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4C1202
Compact Limit Switch That's Also
• Approved by EN, UL, CSA, and CCC (Chinese standard).
• Sealing characteristics that meet IEC IP67 degree of
• Triple-sealed construction:
• Cable lengths of 3 and 5 m available on standard models.
• Multiple mounting possible with Switches with Plungers.
• Models with red LED indicators added to series for easy
• VCTF cables with CE marking.
Model Number Structure
Model Number Legend
Standard Models
D4C-@@@
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
Thin and Highly Sealed
(Ask your OMRON representative for information on
approved models.)
protection.
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Models also available with UL and CSA-certified cables.
confirmation of operation.
(Set by default to light for non-operation.)
(Applicable only to standard models.)
Enclosed Switch
D4C
(1)(2)(3)
(Not all combinations are possible. Ask your OMRON representative for details.)
Pre-wired Models
D4C-@0@@-@@@@@@
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(3) Wiring Specifications
DK1EJ: Pre-wired models
AK1EJ: Pre-wired models
M1J: Connector models for ASI devices
(4) Cable length
03: 0.3 m
Wiring Specifications
(Without operation indicator)
Internal switch
(1)
(3 conductors: DC specification)
(3 conductors: AC specification)
(2 conductors: NO wiring)
COM
NC
NO
(2)
(3)
Connector
Be sure to read Safety Precautions on page 13 to 14 and
Safety Precautions for All Limit Switches.
3
2
4
(4)
Weather-resistant Models
D4C-@@@-P
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(4) Structure
P: Weather-resistant
(1)(2)(3) (4)
CSM_D4C_DS_E_2_1
1

Related parts for D4C-1202

D4C-1202 Summary of contents

Page 1

... Wiring Specifications Internal switch Connector COM CSM_D4C_DS_E_2_1 Weather-resistant Models D4C-@@@-P (1)(2)(3) (4) (1) Rated Current 250 VAC VDC 125 VAC (with LED indicator VDC (with LED indicator 125 VAC, 0 VDC (2) Cable Specifications 2: VCTF oil-resistant cable ( VCTF oil-resistant cable (5 m) (3) Actuator ...

Page 2

... Note: 1. Models are available separately with resistance to viscous oils (oil drain holes are also available), but only with Plunger Models. Add “-M” to the model number (example: D4C-1202 would be D4C-1202-M). 2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details. ...

Page 3

... D4C-2424 D4C-3224 D4C-2524 D4C-3324 D4C-2431 D4C-3231 D4C-2531 D4C-3331 D4C-2432 D4C-3232 D4C-2532 D4C-3332 D4C-2433 D4C-3233 D4C-2533 D4C-3333 D4C-2450 D4C-3250 D4C-2550 D4C-3350 D4C-2460 D4C-3260 D4C-2560 D4C-3360 D4C 0 VDC VCTF oil-resistant VCTF cable *2 cable *1 D4C-3401 D4C-3501 D4C-3402 D4C-3502 D4C-3403 D4C-3503 D4C-3420 D4C-3520 D4C-3424 D4C-3524 ...

Page 4

... D4C-6201 D4C-6301 D4C-6202 D4C-6302 D4C-6203 D4C-6303 D4C-6220 D4C-6320 D4C-6224 D4C-6324 D4C-6231 D4C-6331 D4C-6232 D4C-6332 D4C-6233 D4C-6333 D4C-6250 D4C-6350 125 VAC With operation indicator Without operation indicator D4C-2001-AK1EJ@ D4C-2002-AK1EJ@ D4C-2031-AK1EJ@ D4C-2032-AK1EJ@ D4C-2024-AK1EJ@ D4C VDC With operation indicator D4C-1001-DK1EJ@ D4C-3001-DK1EJ@ D4C-1002-DK1EJ@ D4C-3002-DK1EJ@ D4C-1031-DK1EJ@ ...

Page 5

... Center roller lever Note: 1. The model numbers for heads are of the form D4C-00@@, with the numbers in the squares indicating the type of actuator. 2. Actuators for plunger models, plastic rod models, and center roller lever models cannot be ordered individually. They must be ordered together with the head. ...

Page 6

... Malfunction Ambient operating temperature Ambient operating humidity Weight (D4C-1202) Note: The above figures are initial values. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments ...

Page 7

... Head-mounting Screw Diaphragm The diaphragm is made of silicone rubber and is resistant to temperature changes and adverse weather conditions. Cable Vinyl cabtire cable and is resistant to adverse weather conditions. D4C-4 @@@ , -5 @@@ , -6 @@@ 1,000 700 Operating temperature: 5°C to 35°C 500 Operating humidity: 40% to 70% ...

Page 8

... Use only a straight connector. Note: “Lit when not Actuated” means that when the actuator is in the free position, the indicator is lit, and when the actuator is turned or pushed and the contact comes into contact with the NO side, the indicator turns OFF. D4C , -DK1EJ ) @ @ NC Pin No ...

Page 9

... Spot facing VCTF cable, * 10.2 dia. Depth 0. conductor 2 1.4 Finishing 34 O.D.: 7.6 * S-FLEX VCTF Cables are used for weather-resistant models. D4C-@@20 D4C-@@24 D4C-@@20-P D4C-@@24-P 5.69 N 5.69 N 1.47 N 1.47 N 25° 10°±3° 40° 50° 3° 3° --- ...

Page 10

... Rubber cap 16 +0.2 Two, 5.1 dia. 0 holes Spot facing 10.2 dia. Depth: 6 4.0 7 1.4 1.5 D4C-@@32 D4C-@@33 17.65 N 17.65 N 4.41 N 4.41 N 1 0.2 mm 0.2 mm 34.3±1 mm 34.3±1 mm (5) mm (5) mm D4C 12 dia. x 4.4 stainless steel roller 40 max. Rubber cap PT 25 ± ...

Page 11

... Models with LED Indicator D4C-@@60 The dimensions of the LED 6.67 N indicator for models equipped with 1.47 N one are shown below. 10°±3° 50° 3° --- --- Roller Plunger D4C-@002-@K1EJ@ D4C-@002-M1J@ dia. PT Correct setting position 16 2 max. 51.5 max. 1.5 1.4 6 dia ...

Page 12

... Two, 5.1 dia holes Spot facing 10.2 dia. Depth XS2H-D421 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Sealed Roller Plunger D4C-@032-@K1EJ@ D4C-@032-M1J max. 1.5 1.4 6 dia. D4C-@032 -@K1EJ@ 17.65 N 4. 0.2 mm 34.3± max. 44 ± ...

Page 13

... Movement Differential MD max. 3° * Operation characteristics for the D4C-@@27-P and D4C- @@29-P are for a lever length of 38 mm. Safety Precautions Refer to Safety Precautions for All Limit Switches. Precautions for Correct Use Operating Environment • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals ...

Page 14

... Do not expose the Switch to water exceeding 70°C or use it in steam. • When the D4C is used in a circuit of a device to be exported to Europe, classified as Overvoltage Class III as specified in IEC664, provide a contact protection circuit. • Tighten each screw to a torque according to the following table. ...

Page 15

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords