D4C-1633 Omron Automation, D4C-1633 Datasheet

no-image

D4C-1633

Manufacturer Part Number
D4C-1633
Description
Switch, Limit, SPDT, Sealed CROSS Roller PLUNGER, 5A, 125VAC, PLUG-IN
Manufacturer
Omron Automation
Type
Limitr
Datasheet

Specifications of D4C-1633

Actuator Type
Plunger
Contact Form
1 NC/NO
Current, Rating
5/4 AAC/ADC
Dielectric Strength
1000/1500 VAC
Ip Rating
IP67
Mounting Hole Size
10.2 mm
Mounting Type
Panel
Movement Differential
0.008 in.
Number Of Poles
1
Operating Force
63.49 Oz.
Operating Position
1.35
Over Travel
0.118
Pre Travel
0.07
Release Force
15.87
Special Features
Sealed Crossroller Plunger
Temperature, Operating
-10 to +70 °C
Termination
Screw
Voltage, Rating
250/30 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Compact Limit Switch That's Also
■ Approved by EN, UL, CSA, and CCC (Chinese standard).
■ Sealing characteristics that meet IEC IP67 degree of protection.
■ Triple-sealed construction:
■ Cable lengths of 3 and 5 m available on standard models.
■ Multiple mounting possible with Switches with Plungers.
■ Models with red LED indicators added to series for easy
■ VCTF cables with CE marking.
Model Number Structure
Model Number Legend
Standard Models
D4C-@@@
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
Thin and Highly Sealed
Enclosed Switch
D4C
(Ask your OMRON representative for information on approved models.)
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Models also available with UL and CSA-certified cables.
confirmation of operation.
(Set by default to light for non-operation.)
(Applicable only to standard models.)
(1) (2)(3)
Pre-wired Models
D4C-@0@@-@@@@@@
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(3) Wiring Specifications
DK1EJ: Pre-wired models
AK1EJ: Pre-wired models
M1J: Connector models for ASI devices
(4) Cable length
03: 0.3 m
Wiring Specifications
(Without operation indicator)
Internal switch
(1)
(3 conductors: DC specification)
(3 conductors: AC specification)
(2 conductors: NO wiring)
COM
NO
NC
(2)
(3)
Connector
3
2
4
(4)
Weather-resistant Models
D4C-@@@-P
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(4) Structure
P: Weather-resistant
(1)(2)(3) (4)
1

Related parts for D4C-1633

D4C-1633 Summary of contents

Page 1

... Wiring Specifications Internal switch Connector COM Weather-resistant Models D4C-@@@-P (1)(2)(3) (4) (1) Rated Current 250 VAC VDC 125 VAC (with LED indicator VDC (with LED indicator 125 VAC, 0 VDC (2) Cable Specifications 2: VCTF oil-resistant cable ( VCTF oil-resistant cable (5 m) (3) Actuator ...

Page 2

... D4C-1703 D4C-1420 D4C-1620 D4C-1520 D4C-1720 D4C-1424 D4C-1624 D4C-1524 D4C-1724 D4C-1431 D4C-1631 D4C-1531 D4C-1731 D4C-1432 D4C-1632 D4C-1532 D4C-1732 D4C-1433 D4C-1633 D4C-1533 D4C-1733 D4C-1450 D4C-1650 D4C-1550 D4C-1750 D4C-1460 D4C-1660 D4C-1560 D4C-1760 D4C Microload 0 125 VAC, 0 VDC VCTF oil-resistant VCTF cable *2 cable *1 D4C-4201 D4C-4401 ...

Page 3

... D4C-1@@@ DC-12 2 A/30 V D4C-2@@@ AC-15 2 A/125 V D4C-3@@@ DC-12 2 A/30 V AC-14 0.1 A/125 V D4C-4@@@ DC-12 0.1 A/30 V D4C-5@@@ AC-14 0.1 A/125 V D4C-6@@@ DC-12 0.1 A/30 V UL/CSA B300 (D4C-16@@, -17@@) B150 (D4C-26@@, -27@@) B300 Current(A) Rated voltage Carry current Make Break 120 VAC 240 VAC 15 1 ...

Page 4

... Use only a straight connector. Note: “Lit when not Actuated” means that when the actuator is in the free position, the indicator is lit, and when the actuator is turned or pushed and the contact comes into contact with the NO side, the indicator turns OFF. D4C @ @ , -DK1EJ ) NC Pin No ...

Page 5

... Rubber cap 16 +0.2 Two, 5.1 dia. 0 holes Spot facing 10.2 dia. Depth: 6 4.0 7 1.4 1.5 D4C-@@32 D4C-@@33 17.65 N 17.65 N 4.41 N 4.41 N 1 0.2 mm 0.2 mm 34.3±1 mm 34.3±1 mm (5) mm (5) mm D4C 12 dia. x 4.4 stainless steel roller 40 max. Rubber cap PT 25 ± ...

Related keywords