D4C-1202 Omron, D4C-1202 Datasheet - Page 21

no-image

D4C-1202

Manufacturer Part Number
D4C-1202
Description
SMALL LIMIT SWITCH
Manufacturer
Omron
Series
D4Cr
Datasheets

Specifications of D4C-1202

Rohs Compliant
YES
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
5A @ 250VAC
Actuator Type
Roller Plunger
Mounting Type
Chassis Mount
Termination Style
Cable Leads
Operating Force
1177gf
Actuator Style
Roller Plunger
Operating Force Max
11.77N
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
30V
Contact Current Ac Max
5A
Contact Current Dc Max
4A
Switch Terminals
Cable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4C1202
Mounting
A maximum of 6 Switches may be group-mounted. In this case, pay
attention to the mounting direction so that the convex part of the
group-mounting guide on one Switch fits into the concave part of the
guide on the other Switch as shown in the figure below. For group
mounting, the mounting panel must have a thickness (t) of 6 mm min.
If the mounting panel is warped or has protruding parts, a malfunc-
tion may result. Make sure that the mounting panel is not warped and
has even surfaces.
Mounting Holes
Use a Switch with a rubber cap when using the plunger type in an
environment where malfunction is possible due to environmental
conditions such as dust or cutting chips which may not allow reset-
ting.
180
Cat. No. C032-E1-10
Group-mounting guide
(Front: convex
Rear: concave)
Group Mounting
Group-mounting guide
(Front: convex
Rear: concave)
Enclosed Switch
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Two, 5.2-dia. or M5 screw holes
16 mm
In the interest of product improvement, specifications are subject to change without notice.
D4C
Mounting panel
t
Do not expose the Switch to water exceeding 70 C or use it in steam.
When the D4C is used in a circuit of a device to be exported to
Europe, classified as Overvoltage Class III as specified in IEC664,
provide a contact protection circuit.
Tighten each screw to a torque according to the following table.
Note: By removing the two screws from the head, the head direction
Micro-load Models (D4C-4, -5, -6)
Switching Range
Micro-load models can be used for switching in the range shown
below.
1
2
3
No.
can be rotated 180 . After changing the head direction, re-tight-
en to the torque specified above. Be careful not to allow any for-
eign substance to enter the Switch.
M5 Allen-head bolt
M3.5 head mounting screw
M5 Allen-head bolt
30
24
12
5
0
0.1
Switching
not possible
in this range
5 mW
0.16 mA
Type
1 mA
1
Switching
range for
micro-load
models
10
800 mW
26 mA
4.90 to 5.88 N·m
0.78 to 0.88 N·m
4.90 to 5.88 N·m
100 mA 160 mA
Current (mA)
100
Switching
range for
standard-
load
models
Torque
1,000

Related parts for D4C-1202