Specifications of TC65 TERMINAL

Rohs Compliant
YES
3.5
The power supply of the TC65 Terminal has to be a single voltage source of POWER=8V…30V
capable of providing a peak during an active transmission. The uplink burst causes strong ripples
(drop) on the power lines.
The TC65 Terminal is protected from supply voltage reversal and overvoltage. An internal fuse
ensures an electrical safety according to EN60950. This fuse is not removable.
A fast acting fuse 1.25A with melting integral I²t (0.9 … 1.3 A²s) is necessary to use the TC65
Terminal at a 24V power supply system for vehicles.
The power supply must be compliant with the EN60950 guidelines.
Table 2: Pin assignment of the Western plug for power supply
TC65 Terminal_HD_V01.041
TC65 Terminal Hardware Interface Description
Strictly Confidential / Released
Pin
1
2
3
4
5
6
Signal name
POWER
POWER
EMERGOFF
IGT_IN
GND
GND
Figure 5: Female 6-pole Western plug for power supply, ignition, emergency off
Power Supply
123 4 5 6
Use
Power supply
Power supply
Signal for POWER DOWN mode
Ignition input
Ground
Ground
Pin assignment
1 - POWER
2 - POWER
3 - EMERGOFF
4 - IGT_IN
5 - GND
6 - GND