PAXCDC2C Red Lion Controls, PAXCDC2C Datasheet - Page 16

no-image

PAXCDC2C

Manufacturer Part Number
PAXCDC2C
Description
Extnd. RS232 Card W/9 Pin D Connector
Manufacturer
Red Lion Controls
Datasheet

Specifications of PAXCDC2C

Brand/series
PAXDR
Card Type
Option Communications
Communication
Serial RS232
Data Protocols
7/8 bits, 300 to 19,200 baud, no, even or odd parity
Pax Label Kit
189 Different Engineering Units, Labels Inserted Inside the Unit
Lead Free Status / Rohs Status
RoHS Compliant part
Program lock-out.
by repeatedly pressing the DSP key. An annunciator indicates the display being
shown. These displays can be locked from being visible. It is recommended that
the display be set to
modified. This Programming Mode can be locked with a security code and/or
user input. When locked and the PAR key is pressed, the meter enters a Quick
Programming Mode. In this mode, setpoint, count load and scale factor values
can still be read and/or changed per the selections below. The Display Intensity
Level () parameter also appears whenever Quick Programming Mode is
enabled, and the security code is greater than zero.


6.3 MODULE 3 - D
These displays can be programmed for
Module 3 is the programming for Display lock-out and “Full” and “Quick”
When in the Display Mode, the available displays can be read consecutively
“Full” Programming Mode permits all parameters to be viewed and
SELECTION
Throughout this document, Programming Mode always refers to “Full” Programming (all meter parameters are accessible), unless “Quick
PAR



SECURITY
Programming” is referenced.
CODE
x
3-LOC
Lock-out

Display

>0
>0
>0
Rate x
0
0
0
TOTALIZER A B C DISPLAY LOCK-OUT
rAtE
RATE A B C DISPLAY LOCK-OUT
SELECTION
DESCRIPTION
Visible but not changeable in Quick Programming Mode
Visible and changeable in Quick Programming Mode
Not visible in Quick Programming Mode
CONFIGURED

USER INPUT


not
not




when the corresponding function is not used.




x
Totalizer x
Lockout
Display
DESCRIPTION
Visible in Display Mode
Not visible in Display Mode
tot
USER INPUT
Not Active
Not Active
————
————
Active
Active
STATE



or
Setpoint 1-4

Quick Programming w/Display Intensity
Quick Programming w/Display Intensity
Access
SP-n
.
ISPLAY AND


Quick Programming
“Full” Programming
“Full” Programming
“Full” Programming
PROGRAMMING MODE ACCESS
WHEN PAR KEY IS
PARAMETER MENU
PRESSED
Count Load
Totalizer A
ACntLd
Access


P
ARAMETERS
16
P
ROGRAM
only with a Setpoint Plug-in card installed.
access the “Full” Programming Mode. Access will only be allowed after entering
a matching security code or universal code of
would not have to be configured for Program Lock-out. However, this lock-out is
overridden by an inactive user input configured for Program Lock-out.


Count Load
Totalizer B
TOTALIZER A and B COUNT LOAD ACCESS LOCK-OUT
TOTALIZER A B C SCALE FACTOR ACCESS LOCK-OUT
bCntLd
The setpoint values can be programmed for
Count Load values can be programmed for
The Scale Factor values can be programmed for
Entry of a non-zero value will cause the prompt

Access
“FULL” PROGRAMMING MODE ACCESS
Immediate access.
After Quick Programming with correct code # at
After Quick Programming with correct code # at
Immediate access.
No access
Immediate access.




SETPOINT 1 to 4 ACCESS LOCK-OUT
L
Scale Factor
(
x
Totalizer x

OCK
Access
SCFAC

to
SECURITY CODE



-

OUT
)
x = Rate or Totalizer A, B, and then C


= Setpoints 1 to 4
Security

Code

COdE

. With this lock-out, a user input


,




,


to appear when trying to
,
, or
Pro

prompt.
prompt.
, or


, or

.


. Accessible
.



Related parts for PAXCDC2C