1-6610115-1 Tyco Electronics, 1-6610115-1 Datasheet - Page 3

CONN 1X4 MAG45 MOD GRN/GRN PCB

1-6610115-1

Manufacturer Part Number
1-6610115-1
Description
CONN 1X4 MAG45 MOD GRN/GRN PCB
Manufacturer
Tyco Electronics
Series
Mag45™r
Datasheet

Specifications of 1-6610115-1

Connector Type
RJ45
Number Of Ports
4
Number Of Rows
1
Mounting Type
Panel Mount; Through Hole, Right Angle
Speed
10/100 Base-T
Height Above Board
0.545" (13.84mm)
Led Color
Green - Green
Number Of Cores Per Jack
4
Shielding
Shielded
Tab Direction
Up
Features
AutoMDIX, Board Lock
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rev B
Open circuit inductance.
Random vibration, operational.
Random vibration, non-operational. See Note.
Durability, 500 cycles.
Durability, 2000 cycles.
Mating force.
Unmating force.
Normal force.
Modular plug retention to modular
jack.
Test Description
OCL 350 µH minimum.
No discontinuities of 1 microsecond
or longer duration.
See Note.
See Note.
See Note.
20.02 N [4.5 lbf] maximum.
See Note.
20.02 N [4.5 lbf] maximum.
See Note.
100 gram force [3.53 ozf] minimum
per FCC Part 68, Subpart F
Connector Requirements.
57.83 N [13 lbf] minimum.
Plug shall not disengage from jack.
MECHANICAL
Figure 1 (cont)
Requirement
ANSI X3.263, ref IEEE 802.3.
Measure and record mutual
inductance of mated and mounted
specimens at 100 kHz, 100 mV, 8
mA DC bias, and 25
EIA-364-28D,
Test Condition VIIA.
Subject specimens to 1.0 G rms
between 3-500 Hz. PSD of .003. 45
minutes in each of 3 mutually
perpendicular planes.
EIA-364-28D,
Test Condition VIIA.
Subject specimens to 1.0 G rms
between 3-500 Hz. PSD of .003. 45
minutes in each of 3 mutually
perpendicular planes.
EIA-364-9C.
Manually mate and unmate
specimens with the plug locking tab
inoperable for 500 cycles at a
maximum rate of 300 cycles per
hour.
EIA-364-9C.
Manually mate and unmate
specimens with the plug locking tab
inoperable for 2000 cycles at a
maximum rate of 300 cycles per
hour.
EIA-364-13B.
Measure force necessary to mate
specimens at a maximum rate of
12.7 mm [.5 in] per minute.
EIA-364-13B.
Measure force necessary to
unmate specimens at a maximum
rate of 12.7 mm [.5 in] per minute.
EIA-364-4.
Measure and record normal force
generated at any given deflection
level within the normal operating
range with an FCC compliant
modular plug.
EIA-364-98.
Subject mounted specimens to
specified force applied for 1 minute
in 4 directions with plug mated in
jack and latch engaged.
Procedure
/
C .
108-2100
3 of 7